Complete public upload archive

Property records for 6338 Sean Parkway, St. Louis, MO 63129

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Diagnostic Service — Diagnostic trip fee

  • HVAC

On May 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 6338 Sean Parkway, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Diagnostic trip fee charged for HVAC service visit.

  • HVACWork status not resolved

    Photograph shows a Category I forced air furnace data plate with model number P4HUA12N06401A, serial number WMLM013280, rated at 80,000 BTU/hr input and 64,000 BTU/hr output, equipped for natural gas.

  • HVACWork status not resolved

    Photograph shows an outdoor York air conditioning condenser unit (Model No. H4DB030S06A, Serial No. WNLM003145) with R22 refrigerant, surrounded by leaf debris and showing visible dirt accumulation on the unit exterior.

  • HVACWork status not resolved

    an EnergyGuide label is affixed to the unit

  • HVACWork status not resolved
  • UnclassifiedWork status not resolved

    Photograph shows deteriorated and peeling flooring in the utility area surrounding the furnace, along with a water treatment canister and laundry basket visible to the left of the unit.

  • HVACWork status not resolved

    overgrown vegetation is present around the base of the unit

  • HVACWork status not resolved

    Photograph shows a gas furnace with flexible exhaust flue piping and a service sticker, connected to large sheet-metal supply ductwork running vertically and horizontally in a basement utility room; exposed overhead wiring and wood joists are also visible.

  • UnclassifiedWork status not resolved

    Photograph shows a top-load washing machine, a worn area rug on a concrete floor with debris, and a small stainless steel trash can in the utility room; the space appears cluttered and in poor general condition.

  • HVACWork status not resolved

    Photograph shows a large pleated HVAC air return filter removed from its housing, with heavy accumulation of dust, lint, and debris across the entire filter face and along the edges, indicating the filter is significantly clogged and in need of replacement.

  • HVACWork status not resolved

    the equipment rests among leaf debris in an outdoor setting

  • HVACWork status not resolved

    Photograph shows aging sheet metal ductwork including a round elbow and rectangular duct section; foil/duct tape on the rectangular duct is visibly deteriorated, peeling, and failing, with oxidation and dust accumulation on metal surfaces.

  • HVACWork status not resolved

    Photograph shows an aged tank-style water heater with a galvanized flue vent pipe, copper supply connections, and a cream-colored expansion tank labeled 'House P: 75 / TANK P: 75', installed in a tight utility space with overhead wood framing and adjacent HVAC ductwork.

  • HVACWork status not resolved

    Meld work order for air conditioner issue

  • HVACWork status not resolved

    Photograph shows an open electrical breaker panel mounted on the wall and exposed conduit and wiring running along unfinished ceiling joists in what appears to be a utility or converted garage space.

  • UnclassifiedWork status not resolved

    Photograph shows a cluttered utility room with a washer, multiple laundry baskets, a fire extinguisher, a heat press, a printer, a smart lock on an exterior door, a floor vent on an interior door, and an area rug over a concrete floor.

Record 2Public property record

HVAC System Estimate — 2.5-ton Goodman A/C + 80,000 BTU furnace

  • HVAC

On May 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 6338 Sean Parkway, St. Louis, MO 63129.

Record date

Available findings

  • HVACEstimate or proposed work$8,686

    Estimate for a 2.5-ton Goodman system including a 2.5-ton Goodman air conditioner, 80,000 BTU single stage furnace, evaporator coil, condenser pad, disconnect, install materials and labor.

View 6338 Sean Parkway, St. Louis, MO 63129 on Fresh House