- HVAC · Dual run capacitor supplied for HVAC service · Aug 2026
- HVAC · AC system uses R-22 refrigerant; diagnostic readings recorded · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 6353 Sutherland Avenue, St. Louis, MO 63109. The amount summary includes $289 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Capacitor Service — Dual run capacitor supplied
- HVAC
Built from Housecall Pro data
- $289HVACSupplied a dual run capacitor for HVAC service at 6353 Sutherland Avenue.
- HVACFieldpiece refrigerant diagnostic shows R-22 system with suction pressure 68.0 psig, liquid pressure 190.3 psig, actual superheat 12.0°F, actual subcooling 16.8°F, and Delta T of 19.2°F.
- HVACPhotograph shows the lower exterior of an outdoor HVAC condenser unit with a tan/beige louvered metal cabinet; condenser coil fins are visible through the louver openings and show notable dirt, debris, and buildup accumulation; the unit sits on a base pad over brick paver surface.
- HVACFieldpiece app refrigerant diagnostic shows R-22 system with suction pressure 68.0 psig, liquid pressure 190.2 psig, actual superheat 12.1°F, actual subcooling 16.9°F, and Delta T 19.3°F.
- HVACPhotograph shows the louvered metal side panel of an outdoor HVAC condenser unit with condenser coil fins visible through the stamped slot openings; unit is situated on a brick or paver surface adjacent to a brick wall.
- HVACPhotograph shows a Fluke true RMS multimeter placed on top of a white outdoor HVAC condenser unit, with probes connected and a reading displayed on the LCD screen; orange-handled tools rest on the condenser fan grill nearby, indicating active electrical diagnostic testing of the unit.
- HVACPhotograph shows the exterior side of an outdoor HVAC condenser unit with heavily debris-clogged coil fins visible through the decorative perforated metal panel; the unit is installed in a narrow side passage alongside a stucco wall.