  • HVAC
    HVAC · Dual run capacitor supplied for HVAC service · Aug 2026
  • HVAC
    HVAC · AC system uses R-22 refrigerant; diagnostic readings recorded · 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 6353 Sutherland Avenue. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 6353 Sutherland Avenue, St. Louis, MO 63109. The amount summary includes $289 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Capacitor Service — Dual run capacitor supplied

Document dated Aug 3, 2026Uploaded Nov 8, 20269 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6353 Sutherland Avenue, St. Louis, MO 63109.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $289
  • HVACSupplied a dual run capacitor for HVAC service at 6353 Sutherland Avenue.
    $289
  • HVACFieldpiece refrigerant diagnostic shows R-22 system with suction pressure 68.0 psig, liquid pressure 190.3 psig, actual superheat 12.0°F, actual subcooling 16.8°F, and Delta T of 19.2°F.
  • HVACPhotograph shows the lower exterior of an outdoor HVAC condenser unit with a tan/beige louvered metal cabinet; condenser coil fins are visible through the louver openings and show notable dirt, debris, and buildup accumulation; the unit sits on a base pad over brick paver surface.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+4

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history