6615 Barken Avenue
Across 5 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 5 documented records
Fresh House Property Summary
Highlights selected from 5 documented records for this property.
- HVAC · Incorrectly wired low-voltage rewired, restoring AC to both indoor and outdoor units · Apr 2026
- HVAC · AC no-heat call resolved by resetting tripped breaker and securing thermostat · Apr 2026
- HVAC · Furnace seasonal maintenance performed and filter replaced · Dec 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 5 documented records for 6615 Barken Avenue, St. Louis, MO 63121, dated from January 2026 through April 2026. The amount summary includes $612 in completed work across HVAC, $4,647.60 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Seasonal Maintenance — Filter replaced; system not operating
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance: replaced the filter, found the system did not operate with a flame sensor, and ran the system for 5 minutes with everything working as it should.
- HVACPhotograph shows the interior of a gas furnace with a Honeywell VR8200H 2002 gas valve, multi-port burner manifold assembly, copper gas tubing, and associated wiring; the unit appears aged with visible dust and debris accumulation.
- HVACPhotograph shows a blower motor assembly with extreme dust and debris accumulation coating the motor housing, blower wheel vanes, and multi-colored electrical wiring (red, blue, yellow, green) inside what appears to be an air handler or furnace blower compartment.
- HVACPhotograph shows a heavily soiled 20x20x1 air filter being held in a basement mechanical room with HVAC equipment visible in the background; the filter media appears dark gray with accumulated dust and debris.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit
- HVAC
Built from Housecall Pro data
- HVACService call performed on January 28, 2026 at 6615 Barken Avenue with no service lines itemized.
- HVACcobwebs and grime are visible on the surrounding equipment housing
- HVACPhotograph shows a Carbon Monoxide Meter held at a wall HVAC supply/return register displaying a current CO reading of 053 ppm and a MAX reading of 056 ppm.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Estimate — 80% 75,000 BTU Rheem furnace install
- HVAC
Option: Option #1 $4,647.60 (declined)
Built from Housecall Pro data
- $4,648HVACEstimate for Option #1: 80% 75,000 BTU Furnace (We purpose to install the following equipment in your home), Payment Terms, Terms and Conditions, Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new), Equipment Warranty.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Low-Voltage Repair — Low-voltage rewired, AC restored
- HVAC
Built from Housecall Pro data
- $369HVACLocated and fixed incorrectly wired low-voltage from the bird's nest down to the board on a no-AC call; after rewiring, outdoor and indoor systems started working and the house went from 85° to 83°.
- HVACPhotograph shows the interior of a furnace unit with the access panel removed, revealing a red ECM drive control board (labeled 'ECM DRIVE 24VAC') with extensive multi-colored wiring, a 5-amp fuse/breaker at the top, and the blower housing below; the unit sits on a concrete floor.
- HVACPhotograph shows the interior of a furnace unit with a red control board labeled 'ECM DRIVE-24VAC' and 'FLAME SENSE', with multiple colored wires connected to terminals including PARK, HI HEAT, HUM, ACC, L1, and HSI/CAI.
- HVACPhotograph shows the open control board compartment of an HVAC unit, featuring a red circuit board with multiple labeled terminal blocks (ECM DRIVE-24VAC, HSI, NEUTRALS, ACC, L1) and a dense bundle of multi-colored wiring, along with a 3-amp fuse/breaker.
- HVACPhotograph shows a red HVAC control board with labeled thermostat terminal strip (W1, W2, G, Y2, Y, C, R, DH, L, O, DS) and multiple colored wires connected, along with a white multi-pin connector and a bundle of additional wiring.
- HVACPhotograph shows multiple wire splices joined with yellow wire nuts outside of a junction box in a crawlspace/basement ceiling area, with a Fluke 116 True RMS Multimeter being used to test the connections; wiring includes brown, red, green, white, and black conductors.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Breaker turned off; reset, system running
- HVAC
Built from Housecall Pro data
- $154HVACResponded to a no-AC call, found the furnace had no power because the breaker was off, turned the breaker on so the system ran as intended, and tightened the thermostat to the wall.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.