Complete public upload archive

Property records for 6811 Etzel Avenue, University City, MO 63130

All 3 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 3.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Installation — Furnace opening guarded, new filter installed

  • HVAC

On January 21, 2026, ASSURED HEATING AND COOLING documented HVAC at 6811 Etzel Avenue, University City, MO 63130.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$330

    Addressed failed occupancy inspection for missing furnace panel: installed a new filter, reworked the metal on the filter rack and added a grill so no one can reach inside the running furnace; tested heat and A/C and both functioned, A/C charge not checked due to cold temperatures.

Record 2Public property record

HVAC Diagnostic Service — AC lineset cut and missing; coil needed

  • HVAC

On May 13, 2026, ASSURED HEATING AND COOLING documented HVAC at 6811 Etzel Avenue, University City, MO 63130.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$154

    Diagnosed no-AC call: found AC on with copper lineset cut and missing; needs 21 inch AC coil and 15 ft lineset, and cage will have to be cut and removed.

Record 3Public property record

HVAC Condenser and Coil Replacement — 4-ton 13.4 SEER2 condenser

  • HVAC

On May 27, 2026, ASSURED HEATING AND COOLING documented HVAC at 6811 Etzel Avenue, University City, MO 63130.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$7,725

    Work performed: 4 Ton 13.4 SEER2 R454B W/TXV Coil (We propose to install the following equipment in your home); Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing); Equipment Warranty; Payment Terms; Terms and Conditions; 3/4 - 3/8 Line Set Up To 15ft (We will install new line set from indoor coil to outdoor condenser per code).

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit mounted on a pad along the side of a stucco-clad building, with refrigerant and electrical lines running to a disconnect box mounted on the exterior wall; an HVAC service van is visible in the background.

  • HVACWork status not resolved

    Photograph shows an outdoor AC condenser unit at the base of a stucco wall, with an insulated refrigerant line set and gray electrical conduit running from a wall penetration down to the unit, and a wall-mounted electrical disconnect box; a small black junction box is visible on the ground near the line set.

  • HVACWork status not resolved

    Photograph shows a Guardian brand gas furnace with an evaporator coil section above it, wrapped in foil/plastic insulation, connected to flexible and rigid ductwork and piping, installed in a mechanical closet or utility space.

  • HVACWork status not resolved

View 6811 Etzel Avenue, University City, MO 63130 on Fresh House