- HVAC · Five flex ducts replaced and new return ceiling filter rack installed · Oct 2024
- HVAC · Condensate drain line leak repaired and dual capacitor replaced · Aug 2024
- HVAC · Loose low-voltage wiring repaired across all three HVAC units · May 2025
- HVAC · Third-floor unit drain safety tripped; pan and drain cleared and restored · Sep 2025
- HVAC · Condensing unit checked after roofing tarp placement; found in good working condition · Jun 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 6 documented records for 6833 Waterman Avenue, University City, MO 63130, dated from June 2024 through September 2025. The amount summary includes $3,765.88 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Thermostat miswired; rewired, system working
- HVAC
Built from Housecall Pro data
- $152HVACInspected the non-operating second floor system, found the thermostat wired incorrectly and rewired it so the system functioned; new thermostat wire still needs to be run from the furnace to the second floor thermostat because the wires were very short.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condensate Drain Repair — Condensate PVC drain line repaired
- HVAC
Built from Housecall Pro data
- $533HVACInspected and repaired the condensate PVC drain line leak, cleared and repaired the PVC drain up to 2 fittings, and supplied a 35 + 5 Mfd dual capacitor during a normal hours service call.
- UnclassifiedPhotograph shows a crawl space interior with white PVC piping (including a coupling and elbow), flexible metallic conduit, black electrical cables, wire connectors visible in the background, exposed fiberglass insulation, plastic vapor barrier sheeting on both sides, and wood framing members.

Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Flex Duct Repair — Five 6" flex ducts replaced/repaired
- HVAC
Built from Housecall Pro data
- $2,600HVACReplaced/repaired five 6-inch flex ducts leading to the second and third floors, inspected after repair with airflow greater than before, and installed a new return ceiling filter rack.
- HVACPhotograph shows a large square white ceiling-mounted return air grille with horizontal louvers, installed flush in a white ceiling; minor surface smudges visible on ceiling near the grille.
- HVACPhotograph shows multiple large flexible HVAC ducts running along the attic floor between joists, with dark outer jacketing; fiberglass batt insulation between joists appears compressed and disturbed in several areas beneath the ducts.
- HVACPhotograph shows multiple flexible air ducts in an attic space, including at least one duct with a torn outer jacket exposing white fibrous insulation material beneath; other ducts show signs of wear and aging.
- HVACPhotograph shows a black flexible HVAC duct in a crawl space or attic with a visible tear/hole in the duct jacket and multiple applications of white foam sealant applied as patches along the damaged area, surrounded by pink fiberglass batt insulation and a plastic vapor barrier.
- HVACPhotograph shows heavy accumulation of rodent droppings scattered across pink fiberglass batt insulation in multiple joist bays, with disturbed and soiled insulation visible throughout the attic/crawl space area.
- HVACPhotograph shows multiple HVAC flex ducts and rigid ducts running through an attic space; the center duct's black outer vapor barrier jacket is visibly torn, shredded, and peeling away, exposing white inner insulation material, while debris and apparent animal droppings are scattered on the pink fiberglass insulation below.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call Repair — Loose low voltage wiring repaired, 3 units
- HVAC
Built from Housecall Pro data
- $154HVACFound loose low voltage electrical wiring; repaired and tested all three units, and all systems were working at completion of service.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Condensing unit in good working condition
- HVAC
Built from Housecall Pro data
- $174HVACService call to check the condensing unit's electrical components and pressures/refrigerant levels after a roofing tarp was placed over it; the system was found in good working condition.
- HVACR-410A TXV system subcooling test shows current subcooling of 7° against a recommended 10°; system status is Correct Charge.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Drain Service Call — Cleared clogged HVAC drains, safety tripped
- HVAC
Built from Housecall Pro data
- $154HVACFound the drain safety tripped, and water in the safety pan with a clogged pan drain on the 3rd floor unit; cleared both the secondary pan drain and the drain, and at the end of service the systems were draining properly and safeties were functioning.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.