Document (07/02/2026)

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On July 2, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 6908 Howdershell Road, Hazelwood, MO 63042.

Record date

Available findings

  • PestWork status not resolved

    Wood Destroying Insect inspection at 6908 Howdershell Road found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.

  • Home InspectionWork status not resolved

    Whole-home inspection of 6908 Howdershell Rd, Hazelwood, MO 63042 identified several deficiencies including worn roof shingles, a foundation crack, an inoperable smoke detector, missing laundry GFCI, and a broken window seal; overall home reported in good condition with no structural issues.

  • RoofWork status not resolved

    3-tab shingled roof estimated at 15 years old is showing signs of wear; approximately half a dozen shingles are torn and need replacement; roof is nearing the end of its lifespan.

  • FoundationWork status not resolved

    Crack observed in the front corner of the poured concrete foundation; recommend sealing with urethane caulk; no moisture intrusion was observed in the corresponding area.

  • ElectricalWork status not resolved

    Inoperable smoke detector in the basement needs replacement; GFCI outlet is not present in the laundry room and needs installation; 2-prong ungrounded outlets are present throughout the interior.

  • HVACWork status not resolved

    Rheem central split system (forced air gas heat and 2-ton A/C condenser), manufactured 2019, is functioning correctly; digital thermostat and metal ducting are satisfactory.

  • PlumbingWork status not resolved

    Rheem 50-gallon natural gas water heater manufactured in 2025 is functioning properly; copper supply pipes and PVC waste pipes are satisfactory; T&P relief valve present with blow-off leg.

  • WindowsWork status not resolved

    The front picture window appears to have a broken seal and needs repair or replacement; damage around the window in the front-facing bedroom also needs repair.