HVAC Diagnostic Service — Residential diagnostic service
- HVAC
On January 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7114 Stanford Avenue, University City, MO 63130.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$89
Residential diagnostic service performed.
- HVACWork status not resolved
Photograph shows a basement furnace/air handler with sheet metal ductwork and a metal flue pipe; the air filter has been removed from the unit and is leaning against the wall, visibly dirty and clogged.
- HVACWork status not resolved
Photograph shows two outdoor HVAC condenser units positioned side by side against a white brick exterior wall, both heavily covered with snow on top, with dead leaves and dried vegetation debris accumulated at the base between the units; refrigerant lines are visible running from the right unit into the wall.
- HVACWork status not resolved
Photograph shows a large upflow gas furnace in a basement mechanical room with a galvanized round flue vent pipe, two yellow service company stickers and one green maintenance label affixed to the cabinet, and a copper gas supply line with brass shutoff valve visible on the right side.
- HVACWork status not resolved
Photograph shows a gray metal furnace/air handler unit in a basement utility corridor, with a metal flue pipe assembly routed from the top of the unit upward and laterally, and sheet metal supply ductwork visible overhead.
- HVACWork status not resolved
Photograph shows a State ProLine commercial gas water heater installed in a basement utility space, with copper supply lines connected at the top and a metal flue vent pipe exiting overhead; concrete block walls show some discoloration.
- HVACWork status not resolved
snow and dead vegetation are visible around the unit base
- HVACWork status not resolved
Photograph shows a handheld combustion analyzer displaying an ambient CO reading of 23 PPM CO, below the instrument's CO alarm level of 50 PPM; the measurement has not yet been saved.
- HVACWork status not resolved
- HVACWork status not resolved
Photograph shows a heavily soiled and warped 16x25x1 HVAC air filter being held up, with dense dark debris accumulation across the entire filter surface and visible bowing of the frame; an HVAC return air vent is visible in the background.
- HVACWork status not resolved
Photograph shows the interior of a pipe as viewed on a sewer camera monitor, with a visible longitudinal crack or open joint running along the pipe wall; timestamp on screen reads 06:07:44 2024/03/06.