Property records for 7412 Bear Paw Drive, St. Louis, MO 63129
All 7 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 7.
Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.
HVAC Maintenance Invoice — AC preventative maintenance and cleaning
HVAC
On May 20, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$642
Performed cooling preventative maintenance and cleaning under a one-system maintenance plan, with 410a refrigerant (3 units) and vacuum oil, nitrogen and torch supplies provided.
On December 9, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Available findings
HVACCompleted work
Seasonal heating maintenance performed and a 20/25/1 Merv 11 filter supplied.
Record 3·Public property record
HVAC Maintenance Plan Service — AC preventative maintenance
HVAC
On May 7, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$360
Performed cooling preventative maintenance and cleaning on the AC under a 1-year maintenance plan.
Record 4·Public property record
HVAC Air Conditioner Installation — New air conditioner
HVAC
On July 11, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$5,500
Installed new air conditioner and evaporator with a custom plenum to adapt to existing duct work, evacuated the line set, charged the system with the correct amount of refrigerant, and performed start up testing.
Record 5·Public property record
HVAC Furnace Maintenance — Furnace maintenance under maintenance plan
HVAC
On January 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Available findings
HVACCompleted work
Furnace maintenance performed under the HVAC Maintenance Plan.
Record 6·Public property record
HVAC Maintenance Invoice — Air conditioning maintenance visit
HVAC
On April 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Available findings
HVACCompleted work
Air conditioning maintenance performed under the Residential Maintenance Plan.
HVACWork status not resolved
Photograph shows a ThermoPro digital thermometer reading 54°F inserted into a ceiling air register, with exposed metal ductwork visible in the background.
HVACWork status not resolved
Manufacturer's air conditioner charging information sheet showing normal operating pressures, approach values, subcooling values, and evaporator coil delta-T tables for TXV systems across multiple capacity/model configurations.
HVACWork status not resolved
Live refrigerant diagnostic on R410A system shows vapor pressure 122.9 psi (vapor saturation temp 40.8°F), liquid pressure 199.7 psi (liquid saturation temp 68.1°F), suction line temperature 32.0°F, liquid line temperature 63.3°F, subcooling 4.8°F, and superheat reading invalid (XXX).
HVACWork status not resolved
the non-contact voltage detector LED is illuminated, indicating voltage present
Record 7·Public property record
HVAC Maintenance Invoice — Heating maintenance, maintenance plan
HVAC
On October 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.
Record date
Available findings
HVACCompleted work
Heating maintenance performed under the Residential Maintenance Plan.
HVACWork status not resolved
Photograph shows a small electric motor (part number 1186530, model AS-3200UTCFC-AL AOM, made in Vietnam by Sunshiny) mounted inside an HVAC blower/inducer housing, with two red spade-connector wires attached to its terminals.
HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter reading 5.6 AAC being used on wiring at an HVAC air handler unit, with a multi-colored wire bundle and plumbing pipes visible in the background.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter reading 5.6 amps (AC current mode) being held in front of an HVAC air handler unit with visible wiring connections.