Record 1Public property record

HVAC Maintenance Invoice — AC preventative maintenance and cleaning

  • HVAC

On May 20, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$642

    Performed cooling preventative maintenance and cleaning under a one-system maintenance plan, with 410a refrigerant (3 units) and vacuum oil, nitrogen and torch supplies provided.

Record 2Public property record

HVAC Heating Maintenance — Seasonal heating maintenance

  • HVAC

On December 9, 2024, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    Seasonal heating maintenance performed and a 20/25/1 Merv 11 filter supplied.

Record 3Public property record

HVAC Maintenance Plan Service — AC preventative maintenance

  • HVAC

On May 7, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$360

    Performed cooling preventative maintenance and cleaning on the AC under a 1-year maintenance plan.

Record 4Public property record

HVAC Air Conditioner Installation — New air conditioner

  • HVAC

On July 11, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$5,500

    Installed new air conditioner and evaporator with a custom plenum to adapt to existing duct work, evacuated the line set, charged the system with the correct amount of refrigerant, and performed start up testing.

Record 5Public property record

HVAC Furnace Maintenance — Furnace maintenance under maintenance plan

  • HVAC

On January 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    Furnace maintenance performed under the HVAC Maintenance Plan.

Record 6Public property record

HVAC Maintenance Invoice — Air conditioning maintenance visit

  • HVAC

On April 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    Air conditioning maintenance performed under the Residential Maintenance Plan.

  • HVACWork status not resolved

    Photograph shows a ThermoPro digital thermometer reading 54°F inserted into a ceiling air register, with exposed metal ductwork visible in the background.

  • HVACWork status not resolved

    Manufacturer's air conditioner charging information sheet showing normal operating pressures, approach values, subcooling values, and evaporator coil delta-T tables for TXV systems across multiple capacity/model configurations.

  • HVACWork status not resolved

    Live refrigerant diagnostic on R410A system shows vapor pressure 122.9 psi (vapor saturation temp 40.8°F), liquid pressure 199.7 psi (liquid saturation temp 68.1°F), suction line temperature 32.0°F, liquid line temperature 63.3°F, subcooling 4.8°F, and superheat reading invalid (XXX).

  • HVACWork status not resolved

    the non-contact voltage detector LED is illuminated, indicating voltage present

Record 7Public property record

HVAC Maintenance Invoice — Heating maintenance, maintenance plan

  • HVAC

On October 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7412 Bear Paw Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    Heating maintenance performed under the Residential Maintenance Plan.

  • HVACWork status not resolved

    Photograph shows a small electric motor (part number 1186530, model AS-3200UTCFC-AL AOM, made in Vietnam by Sunshiny) mounted inside an HVAC blower/inducer housing, with two red spade-connector wires attached to its terminals.

  • HVACWork status not resolved

    Photograph shows a Fluke 323 True RMS Clamp Meter reading 5.6 AAC being used on wiring at an HVAC air handler unit, with a multi-colored wire bundle and plumbing pipes visible in the background.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a Fluke 323 True RMS Clamp Meter reading 5.6 amps (AC current mode) being held in front of an HVAC air handler unit with visible wiring connections.

View 7412 Bear Paw Drive, St. Louis, MO 63129 on Fresh House