Record 1Public property record

HVAC Capacitor Service — Dual run capacitor supplied, diagnostic

  • HVAC

On September 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 7430 General Sherman Lane, St. Louis, MO 63123.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$540

    Supplied a dual run capacitor and performed an overtime diagnostic at the residence.

  • HVACWork status not resolved

    Photograph shows a red ThermoPro digital thermometer inserted into a metal HVAC duct or plenum in a mechanical room, with copper pipes and additional ductwork visible in the background, indicating a temperature measurement being taken at the duct.

  • HVACWork status not resolved

    Photograph shows the side grille panels of a gray outdoor HVAC condenser unit with coils visibly packed with heavy accumulations of dirt, debris, grass clippings, and organic matter, significantly restricting airflow through the unit; dry grass and weeds are present at the base.

  • HVACWork status not resolved

    Photograph shows the exterior side panel of an outdoor HVAC condenser unit with condenser coil fins visibly packed with grass clippings, dirt, and organic debris through the louvered housing slots.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with condenser coil fins visibly packed with pine needles, dirt, and organic debris through the louvered side panel, indicating significant airflow restriction.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with coils visibly packed with pine needles, dirt, and organic debris through the louvered side panel; red meter leads and a power tool are present at the unit.

  • HVACWork status not resolved

    A4AC3029A1000BA, Serial No. 21252F79BF, manufactured June 2021, rated 208/230V, 1-phase, 60Hz, with HFC-410A refrigerant

  • HVACWork status not resolved

    Fieldpiece app refrigerant side measurements for R-410A system: suction pressure 115.4 psig, liquid pressure 326.9 psig, actual superheat 27.1°F, actual subcooling 3.1°F, vapor saturation 38.6°F, liquid saturation 101.8°F.

  • HVACWork status not resolved

    Photograph shows an outdoor AC condenser unit with louvered side panels; condenser coil fins visible through the slots appear heavily clogged with pine needles, dirt, and organic debris, significantly restricting airflow.

  • HVACWork status not resolved

    Fieldpiece app refrigerant measurement shows R-410A system with suction pressure 131.3 psig, liquid pressure 337.6 psig, actual superheat 33.7°F, and actual subcooling 2.8°F — indicating potentially low refrigerant charge.

  • HVACWork status not resolved

    Photograph shows a digital thermometer with a red housing displaying a reading of 85.6°F, placed against a light gray surface.

  • HVACWork status not resolved

    condenser coil fins visible through the slats appear darkened with debris accumulation

  • HVACWork status not resolved

    Photograph shows a digital refrigerant diagnostic app screen displaying R-454B refrigerant readings: suction pressure 130.5 psig, suction temperature 80.9°F, vapor saturation 50.4°F, actual superheat 30.5°F; liquid pressure 282.1 psig, liquid temperature 89.6°F, liquid saturation 95.5°F, actual subcooling 5.9°F, discharge pressure 130.5 psig.

  • HVACWork status not resolved

    Photograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 131.8 psig, suction temp 80.0°F, vapor saturation 45.6°F, actual superheat 34.4°F; liquid pressure 341.4 psig, liquid temp 102.2°F, liquid saturation 104.9°F, actual subcooling 2.7°F, discharge pressure 131.8 psig.

  • HVACWork status not resolved

    Maintenance request submitted for no air conditioning with indoor temperature exceeding 85°F

  • HVACWork status not resolved
  • UnclassifiedWork status not resolved

    Photograph shows an iPhone calculator app screenshot displaying the arithmetic expression 67 minus 85 with a result of negative 18; no property-related content is present.