On August 4, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 7541 Norwalk Lane, St. Louis, MO 63121.
- Record date
Available findings
- SewerWork status not resolved
Sewer lateral line is completely blocked with debris and tree roots; two sections of the cast-iron pipe are cracked allowing root intrusion — hydroflushing and sleeve repairs at both cracks are recommended.
- PestWork status not resolved
Visible evidence of wood destroying insects found: older termite damage present on wood exterior door trim; no live insects observed; treatment with borate-based solution recommended.
- ElectricalWork status not resolved
Exterior GFCI outlet at front corner is broken, won't reset, and is loose from the wall; two outlets in the rear add-on room have reversed hot/neutral wiring and a loose mounting; laundry area lacks GFCI-protected outlet; kitchen exhaust fan is inoperable with no power.
- FoundationWork status not resolved
Poured concrete foundation is in satisfactory condition; common corner cracks observed and inspector recommends sealing with heavy-duty epoxy paste; no moisture detected in basement.
- Home InspectionWork status not resolved
Whole-home inspection of single-family property identified multiple deficiencies including a blocked sewer lateral, broken exterior GFCI outlet, inoperable kitchen exhaust fan, broken thermostat, disconnected fireplace flue handle, cracked basement windows, and older termite damage; roof (1-3 years old) and structure were satisfactory with no structural issues noted.
- HVACWork status not resolved
Thermostat battery door is broken and keeps popping open, canceling the HVAC system and requiring repair or replacement; Goodman central split system (2.5-ton A/C, mfgd 2019) and Goodman forced-air gas furnace are otherwise functioning satisfactorily.
- PestWork status not resolved
Older termite damage is visible on the exterior door trim with no other signs of active infestation found; treatment with a borate-based solution (e.g., Bora-Care) is recommended unless seller can prove prior treatment.
- PlumbingWork status not resolved
State brand 40-gallon natural gas water heater (manufactured 2019) is functioning properly; copper supply pipes are satisfactory; sump pump not present.
- RoofWork status not resolved
Architectural shingle roof estimated 1-3 years old is installed correctly and in satisfactory condition; gable-end ventilation, metal vent stacks, gutters, and downspouts are all satisfactory.
- SewerWork status not resolved
The sewer lateral line is completely blocked with debris and tree roots; two sections of the cast-iron portion are cracked, allowing root intrusion — lateral requires hydroflushing and sleeve repairs at the two cracks.
- WindowsWork status not resolved
Front living room window will not lock — lock mechanism is loose and needs securing; two basement glassblock windows have small cracks and need repair or replacement; fireplace flue handle in living room is disconnected and will not open the flue.