- HVAC · AC drain redone, coil leveled, filter rack and line set insulation added · Jul 2025
- HVAC · AC found with multiple refrigerant leaks and improper coil installation · Jul 2025
- HVAC · Furnace blower cleaned, flame sensor cleaned, pressure switch line replaced · Dec 2025
- HVAC · Thermostat and control board wiring corrected; AC and blower restored · May 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 7830 Blandford Drive, Normandy, MO 63121, dated from May 2025 through December 2025. The amount summary includes $2,480.78 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance — Miswired thermostat/board corrected; AC runs
- HVAC
Built from Housecall Pro data
- $349HVACService call for AC not working: found wires not hooked up correctly at the thermostat and board, corrected the wiring, and the blower and condenser now operate with good system pressures.
- HVACPhotograph shows a mobile app superheat test result for a non-TXV R-410A system; current superheat reads 10° against a required superheat of 15°, with system status displayed as 'Correct Charge'.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Poor unpermitted install, low refrigerant
- HVAC
Built from Housecall Pro data
- $469HVACService call for AC not cooling: found unpermitted, poorly done install with multiple leaks, coil installed at wrong level and angle, and dirty outdoor unit low on refrigerant; charged system with 2.5 pounds of R-410A with stop leak, and system was cooling but needs further repairs (filter rack, drain redo and coil leveling, line set insulation).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Work — Filter rack, coil drain redo, line set insulation
- HVAC
Built from Housecall Pro data
- $1,250HVACCorrected system issues: added filter rack, redid drain and leveled coil, and added insulation to entire line set.
- HVACPhotograph shows a furnace/air handler unit with its access panel open and a white drain or condensate line running across a wet concrete floor toward a large pool of standing water on the right side of the basement utility area.
- HVACPhotograph shows large rectangular galvanized sheet metal ductwork, a foam-insulated suction line, and a copper refrigerant line running vertically in what appears to be a crawl space or basement mechanical area; ductwork surfaces appear dusty.
- HVACPhotograph shows a furnace/air handler unit with its access panel open and internal components exposed, situated on a concrete floor covered with standing water, mud, and debris; white condensate or drain tubing runs from the unit across the wet floor.
- HVACPhotograph shows a residential furnace and attached sheet metal plenum/duct box in a basement mechanical room; the filter access slot on the plenum appears open or unfiltered, the duct and furnace surfaces are heavily soiled with dust and grime, and the concrete floor immediately in front of and around the base of the equipment shows visible wet staining and moisture accumulation.
- HVACexposed wood framing and an electrical disconnect box are also visible
- HVACa water heater is visible in the background
- HVACblack iron gas pipe and electrical wiring are also visible
- HVACPhotograph shows a sheet metal duct plenum with a visible open gap or slot on its face, a furnace/air handler unit with exposed wiring to the right, and a dirty concrete floor with debris; the open duct gap is a notable condition.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC No Heat Repair — Dirty blower motor caused high-limit shutoff
- HVAC
Built from Housecall Pro data
- $413HVACNo heat service call: cleaned the blower motor caked with dog hair and grime that caused the system to overheat and shut off on high limit, cleaned the flame sensor, and replaced the pressure switch rubber line; system ran properly after repairs.
- HVACPhotograph shows an HVAC blower motor and squirrel-cage housing heavily coated in dust, lint, and debris, with multiple electrical wires routed alongside the motor; surrounding sheet metal shows rust and corrosion, and cobwebs are visible in the cabinet.
- HVACPhotograph shows an HVAC blower motor and squirrel-cage blower wheel with heavy accumulation of dust, lint, and debris on all surfaces, including the motor housing, blower wheel blades, cabinet interior walls, and wiring; cobwebs are also present throughout the compartment.
- HVACPhotograph shows an HVAC squirrel-cage blower wheel with heavy accumulation of dust, lint, and debris coating the blades and hub area, indicating significant buildup that would restrict airflow.
- HVACPhotograph shows heavily corroded and deteriorated pipe or fitting components piled on a concrete floor, with a pair of pliers nearby and white mineral deposits scattered across the floor surface.