HVAC Inspection and Maintenance — A/C inspection and cleaning
- HVAC
On June 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 803 Bordeaux Court, Ballwin, MO 63011.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$203
Air conditioning inspection and cleaning: checked air conditioner operation, cleaned coils, checked refrigerant charge, contactor, capacitor and motor outputs.
- HVACWork status not resolved
Maintenance request logged for air conditioner issue
- HVACWork status not resolved
Fieldpiece refrigerant diagnostic shows R-410A system with suction pressure 121.6 psig, discharge pressure 488.7 psig, actual superheat 21.6°F, actual subcooling 10.6°F; air side diagnostics indicate supply dry bulb (54.6°F) is above target (50.7°F), suggesting low capacity.
- HVACWork status not resolved
Photograph shows Fieldpiece app screen displaying R-410A refrigerant measurements: suction pressure 123.2 psig, liquid pressure 509.8 psig, actual superheat 19.0°F, actual subcooling 20.5°F, and Delta T 13.3°F.
- HVACWork status not resolved