Complete public upload archive

Property records for 8118 Blanchard Drive, Berkeley, MO 63134

All 3 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 3.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Service Call — Furnace drain hose misrouted, leak fixed

  • HVAC

On July 1, 2025, ASSURED HEATING AND COOLING documented HVAC at 8118 Blanchard Drive, Berkeley, MO 63134.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Service call for a leaking furnace: found the drain hose wrapped around the humidifier, causing condensation to build up and overflow the drain pan; readjusted the hose to the drain and cleared debris so it drained properly.

Record 2Public property record

HVAC Seasonal Maintenance — Furnace pressure switch sticking

  • HVAC

On November 7, 2025, ASSURED HEATING AND COOLING documented HVAC at 8118 Blanchard Drive, Berkeley, MO 63134.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Seasonal maintenance performed: ran the furnace through its operations and found the pressure switch sticking randomly and the blower motor and fan wheel caked in dirt; pressure switch replacement and blower wheel and motor removal and cleaning were recommended as repairs beyond a basic clean and check.

  • HVACWork status not resolved

    Photograph shows an HVAC blower wheel (squirrel cage fan) with heavy dust and debris accumulation coating the blades, shroud, and housing; the central shaft set screw shows visible rust/corrosion.

  • HVACWork status not resolved

    Photograph shows an HVAC blower assembly with a squirrel-cage fan wheel and motor heavily coated in accumulated dust and debris; the motor housing has a thick matted layer of lint/dust buildup, and visible rust is present on surrounding metal components.

  • HVACWork status not resolved

    Photograph shows interior of a gas furnace with access panel open, multiple burners actively firing with blue flames, gas valve assembly, inducer motor, and wiring harness visible; EnergyGuide and hazardous voltage warning labels affixed to cabinet.

  • HVACWork status not resolved

    an EnergyGuide label and a service sticker on the ductwork are visible

  • HVACWork status not resolved
Record 3Public property record

HVAC Blower Service — Blower cleaned, pressure switch tubing replaced

  • HVAC

On January 6, 2026, ASSURED HEATING AND COOLING documented HVAC at 8118 Blanchard Drive, Berkeley, MO 63134.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$625

    Cleaned blower and wheel, replaced pressure switch tubing and cleaned ports.

  • HVACWork status not resolved

    Photograph shows a squirrel-cage blower wheel and motor assembly with heavy dust accumulation on the wheel blades and housing; visible rust/corrosion on the metal mounting bracket; a motor wiring label is visible showing multi-speed tap wiring diagram (HI, M-HI, M-LO, LO) with color-coded leads.

  • HVACWork status not resolved

    Photograph shows an HVAC blower motor with heavy dust and debris accumulation on the motor body, end cap, and surrounding squirrel-cage blower assembly; colored wiring (red, yellow) exits the motor.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with three burner ports producing active blue flames; a flame sensor/igniter probe is visible on the right burner, wiring harnesses connect to limit switches on the left, and the burner tray shows dust and debris accumulation.

  • HVACWork status not resolved

    Photograph shows a heavily dust-laden HVAC blower motor with a thick accumulation of compacted debris coating the motor housing, mounting bracket, and surrounding cabinet surfaces, along with visible colored electrical wiring.

  • HVACWork status not resolved

    Photograph shows two reddish-orange flexible rubber or silicone tubes laid out on a gray painted concrete floor, with a worn boot partially visible in the upper right corner.

  • HVACWork status not resolved

    Photograph shows a squirrel-cage blower wheel with heavy accumulation of dust and debris on the blades and hub; a rusted bolt is visible at the center shaft, and a part label sticker (partial text: 70-22683-01) is affixed to the wheel face.

View 8118 Blanchard Drive, Berkeley, MO 63134 on Fresh House