Hi, I'm 836 North Taylor Avenue. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
836 North Taylor Avenue
Kirkwood, MO 6312238.5951°N, 90.4035°W
1Event
Contributed by:1 contributor
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · A 2008 York furnace received a heating maintenance service including filter replacement, flame sensor cleaning, drain clearing, and gas pressure and temperature rise testing; the heat exchanger was confirmed free of rust or cracks. · Oct 2026
- HVAC · The furnace's inducer motor was noted as noisy with failing bearings and identified as the likely next component to fail; the blower motor capacitor tested at 13 μF against a 15 μF rating, and the homeowner expressed intent to replace the furnace at the next major repair. · Oct 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Oct 2026
Latest documented event: Oct 2026
First added to Fresh House: Oct 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 836 North Taylor Avenue, Kirkwood, MO 63122, dated in October 2026.
HVAC
HVAC Heating Maintenance — Noisy inducer motor; bearings failing
Document dated Oct 19, 2026Uploaded Oct 22, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 836 North Taylor Avenue, Kirkwood, MO 63122.
Scope
- HVAC
Contributor
worked on or inspected it- HVACPerformed heating maintenance on a 2008 York furnace: replaced filter, cleaned flame sensor and internals, blew out drains, tested blower motor capacitor (13 μF of 15), confirmed heat exchanger free of rust or cracks, and tested gas pressure and temperature rise (30°F low / 70°F high); inducer motor noted as noisy with failing bearings and identified as likely next component to fail; customer expressed desire to replace furnace at next major repair.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,