HVAC Seasonal Maintenance — Plenum needs sealing; p-trap suggested
- HVAC
On November 5, 2025, ASSURED HEATING AND COOLING documented HVAC at 8748 JORDAN, St. Louis, MO 63147.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$89
Seasonal maintenance performed: air handler found off, thermostat set to call for heat, high voltage checked on all four legs (21 to 24 volts), heat kit working as intended; recommended a better filter slot, sealing the plenum, and adding a p-trap to the pinched pump line.
- HVACWork status not resolved
Photograph shows an air handler unit with Shurtape AF 099 foil-taped ductwork connections, a condensate pump (black unit on concrete floor with visible POWER and ALARM indicator lights), and flexible braided condensate lines routed from the air handler to the pump.
- HVACWork status not resolved
Photograph shows an upflow air handler unit installed in a mechanical room, with copper refrigerant lines at the base, sheet metal supply ductwork connected at the top, a condensate drain line, and multiple manufacturer warning and EnergyGuide labels affixed to the front panel; debris and loose insulation material are visible on the floor around the unit base.
- HVACWork status not resolved
Photograph shows large rectangular galvanized sheet metal ductwork (plenum/trunk line) in a basement or mechanical space, with foil-faced tape that appears loose or improperly adhered at the top duct joint; flexible metallic conduit and electrical wiring are also visible nearby.
- HVACWork status not resolved
Photograph shows sheet metal ductwork with a visible open gap and torn/crumpled foil tape at a duct joint, indicating a failed or incomplete seal; a round metal pipe and flexible metallic conduit are also visible in the same utility space.
- HVACWork status not resolved