- HVAC · HVAC service visit trip fee charged · Sep 2026
- HVAC · Refrigerant readings indicated a likely low charge condition · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 8817 Lynn Lane, St. Louis, MO 63127. The amount summary includes $89 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Trip fee for service visit
- HVAC
Built from Housecall Pro data
- $89HVACTrip fee charged for an HVAC service visit.
- HVACPhotograph shows an outdoor HVAC condenser unit data plate with model number 116BNA018-B, serial number 2622E18054, factory charged with R410A refrigerant (4.60 lbs), rated 208-230V/1PH/60Hz, manufactured June 2022.
- HVACno heat pack installed
- HVACPhotograph shows Fieldpiece app refrigerant side readings: suction pressure 156.5 psig at 56.7°F (vapor saturation 55.1°F); liquid pressure 385.1 psig at 98.3°F (liquid saturation 113.6°F); air-side measurements (wet bulb, relative humidity, dew point, enthalpy, delta T) all show no reading.
- HVACFieldpiece app shows R-410A refrigerant readings: suction pressure 71.0 psig, liquid pressure 283.5 psig, actual superheat 65.5°F (very high), and actual subcooling -1.6°F (negative), indicating a likely low refrigerant charge condition.
- HVACPhotograph shows Fieldpiece app refrigerant measurements for an R-22 system: suction pressure 148.7 psig, liquid pressure 148.6 psig, actual superheat 9.2°F, actual subcooling -12.5°F, and discharge pressure 148.7 psig.
HVAC