Complete public upload archive

Property records for 900 Burgundy Lane, Ballwin, MO 63011

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Heating Maintenance — Seasonal heating maintenance

  • HVAC

On March 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 900 Burgundy Lane, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$145

    Seasonal heating maintenance performed, along with a residential diagnostic service.

  • HVACWork status not resolved

    Photograph shows a UEI EM152 digital manometer displaying a differential pressure reading of -1.74 inH2O, connected via tubing to HVAC equipment; stacked 16x20x1 Basic 7500 Allergen air filters and associated ductwork and piping are visible in the background.

  • HVACWork status not resolved

    Photograph shows a metal louvered HVAC air vent or register with heavy accumulation of gray dust and debris coating the slats and surrounding sheet metal housing.

  • HVACWork status not resolved

    Photograph shows the interior of an open HVAC unit with a large accumulation of nesting material (dry grass, straw, and twigs) built around the conduit and wiring, posing a fire and operational hazard.

  • HVACWork status not resolved

    Photograph shows a PDT650 pocket thermometer reading 140.3°F placed against a galvanized metal supply duct, with a furnace/air handler cabinet visible above and refrigerant line set to the right.

  • HVACWork status not resolved

    Photograph shows a UEI PDT650 pocket thermometer attached to a galvanized sheet metal HVAC duct or plenum, displaying a temperature reading of 109.0°F.

  • HVACWork status not resolved

    Photograph shows a UEI PDT650 pocket thermometer probed into a sheet-metal duct surface reading 80.4°F, with 'AIRFLOW' and a directional arrow marked in blue on the duct.

  • HVACWork status not resolved

    Photograph shows a sewer camera inspection monitor displaying the interior of a pipe with visible buildup, discoloration, and scale/corrosion deposits along the pipe walls at what appears to be a bend or joint; camera temperature reads 114°F and timestamp reads 03-10-2026 12:28.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows the interior data plate of a Rheem gas furnace (model RGRA-10EZAJS, serial EJ5D707F320003657), rated at 105,000 BTU/hr input (30.77 kW), 115V/60Hz/1Ph, factory equipped for natural gas, with a 3/4 HP blower motor.

  • UnclassifiedWork status not resolved

    Photograph shows the interior of a red plastic bucket viewed from above, with accumulated dirt, dried grass clippings, pine needles, and organic debris at the bottom; the bucket is situated outdoors on or near a grassy surface.

Record 2Public property record

HVAC Maintenance Invoice — Dual run capacitor and heating maintenance

  • HVAC

On March 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 900 Burgundy Lane, Ballwin, MO 63011.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$115

    Supplied a dual run capacitor and performed seasonal heating maintenance, with a warranty credit applied from a previous visit.

View 900 Burgundy Lane, Ballwin, MO 63011 on Fresh House