- HVAC · Condenser fan replaced at the outdoor AC unit · Jun 2026
- HVAC · AC system thawed, capacitor replaced, refrigerant topped off · Jun 2025
- HVAC · Frozen coil and extremely dirty filter found at furnace · Jun 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 9224 Glen Garden Drive, Jennings, MO 63136, dated from June 2025 through June 2026. The amount summary includes $2,239.55 in completed work across HVAC, $154 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Frozen coil from extremely dirty filter
- HVAC
Built from Housecall Pro data
- $154HVACService call for water around the base of the furnace; found an extremely dirty filter and a frozen coil, drain not clogged, and tenant was told to replace the filter.
- HVACPhotograph shows the interior of an open air handler cabinet with a vertical copper refrigerant line, insulated evaporator coil assembly, a white PVC condensate drain line with trap fitting, and a large insulated flexible supply duct connected to the unit.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service Call — Bad capacitor replaced; refrigerant added
- HVAC
Built from Housecall Pro data
- $463HVACSystem was thawed out from ice; pressures at the condensing unit were a little low and a bad 40+5 capacitor was replaced, less than a pound of refrigerant was added, and the system worked as intended.
- HVACR-410A TXV system subcooling diagnostic shows current subcooling of 9° against a recommended 10°; system status is Correct Charge.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Bad condenser fan on outside AC unit
- HVAC
Built from Housecall Pro data
- $154HVACService call for AC unit not running; on arrival the outside condenser fan was found to be bad, and an estimate will be sent.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condenser Fan Replacement — Condenser fan replaced
- HVAC
Built from Housecall Pro data
- $1,623HVACReplaced condenser fan.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.