- HVAC · Refrigerant leak stop applied and refrigerant recharged · Oct 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 9252 Citadel Court, St. Louis, MO 63123. The amount summary includes $699 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Service — Refrigerant leak stop and recharge
- HVAC
Built from Housecall Pro data
- $699HVACApplied refrigerant leak stop and added refrigerant charge (3 lbs max) to the system, plus a trip fee.
- HVACPhotograph shows a CPS digital refrigerant scale displaying 0 lbs and 12.00 oz, with a yellow refrigerant hose visible on a concrete floor.
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R-410A refrigerant readings: superheat (SH) 8.2°F, subcooling (SC) 10.6°F, low-side pressure 107.5 psi, and high-side pressure 250.2 psi, held in front of an outdoor condenser unit.
- HVACPhotograph shows an HVAC air filter or coil fins with heavy accumulation of dark fibrous debris; dust, lint, and hair; densely packed between the filter frame slats, indicating a severely clogged filter in need of replacement.
- HVACPhotograph shows flexible metal ductwork running along the left concrete wall of the basement.
- HVACPhotograph shows the louvered side panel of an outdoor HVAC condenser unit with aluminum coil fins visible behind the louvers; minor debris and dust accumulation are visible on the grille and fins.
- HVACPhotograph shows a Lennox gas furnace with its access panel open and an air filter removed and leaning against the unit; the filter appears yellowed and dirty, and a red 'IMPORTANT' label sticker is visible on the adjacent ductwork.
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R410A refrigerant readings at an outdoor condenser unit: low-side 109.2 psi with 10.9°F superheat (SH), high-side 246.1 psi with 5.0°F subcooling (SC).
- UnclassifiedPhotograph shows black wiring or cables routed along a heavily dust-covered dark plastic housing with ribbed/serrated edges; a thin black wire or rod runs diagonally across the frame.