Hi, I'm 9525 Stansberry Avenue. I only speak from this property's source-backed records — 10 documents from 4 contributors. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
9525 Stansberry Avenue
Across 10 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 10 documented records
Fresh House Property Summary
Highlights selected from 10 documented records for this property.
- HVAC · New 3-ton air conditioner and evaporator coil installed · 2026$5.7k
- HVAC · Furnace serviced after gas utility flagged it as dangerous · 2025
- HVAC · AC system found oversized for home size causing humidity issues · 2026
- Sewer · Sewer lateral open and serviceable; light root growth in clay sections noted · Aug 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 10 documented records for 9525 Stansberry Avenue, St. Louis, MO 63134, dated from August 2025 through July 2026. The amount summary includes $5,745 in completed work, $14,878 in estimates, $596 with completion status not stated; appraisal values and permit-declared valuations are excluded.
HVAC Condenser Replacement Estimate — 3-ton Rheem condenser and TXV
- HVAC
Option: Option #1 $6,754 (declined)
Built from Housecall Pro data
- $6,754HVACEstimate for Option #1: Equipment Warranty, Terms and Conditions, Condenser Only Description (This install includes Pad, electrical whip and fused disconnect), 3 Ton 13.4 SEER2 R454B W/TXV Coil (We propose to install the following equipment in your home).
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Estimate — 2.5-ton A/C + 80% furnace, declined
- HVAC
Option: Option #1 $8,124 (declined)
Built from Housecall Pro data
- $8,124HVACEstimate for installing a 2.5 ton 13.4 Seer2 Rheem condenser, TXV cased coil and 80% 75,000 BTU gas furnace, including fused disconnect, whip, pad, line set flush, flue pipe, gas shut off and startup.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Sewer Camera Inspection — Lateral open; root growth in clay line noted
This record, dated August 7, 2025, documents Sewer at 9525 Stansberry Avenue, St. Louis, MO 63134.
- Sewer
- SewerSewer lateral line is open and serviceable with no visual defects; light root growth observed in clay sections with annual maintenance (camera re-inspection) recommended in one year; no immediate service required.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Recorded Jul 2026
This record, dated July 23, 2026, documents Appraisal at 9525 Stansberry Avenue, St. Louis, MO 63134.
Appraisal information extracted from an uploaded appraisal document.
HVAC System Installation — RunTru 3-ton 13 SEER A/C installed
- HVAC
- $5,745HVACInstalled new Run Tru 3 ton 13 SEER air conditioner with matching cased insulated evaporator coil, including new condenser pad, electrical disconnect box, condensate drain system, sheet metal plenum transition, and removal/haul away of existing system; mechanical permit included.
Documented warranty10 year / 1 yearFrom invoiceView details
- parts
View source wording
“10 year parts warranty”
- compressor
View source wording
“10 year compressor”
- labor
View source wording
“1 year labor”
Coverage based on invoice. Start date, ownership or occupancy, service territory, product or ordered options, transferability, and exclusions may affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — 4-ton system oversized for 900 sq ft home
- HVAC
- $89HVACResidential diagnostic service call: checked indoor air filters, corrected thermostat from Celsius to Fahrenheit and set to call for cooling, and checked system performance; technician noted the 4-ton system is oversized for the 900 sq ft home, causing humidity control issues, and recommends installing a properly sized AC and furnace.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Tune-Up — Furnace tagged dangerous by Spire gas
- HVAC
- $214HVACPerformed diagnostic service call and furnace precision tune-up and cleaning after Spire tagged the furnace as dangerous due to gas line pressure issues; technician performed leak search, found no leaks, conducted PTU, cycled furnace with no errors, and showed tenant how to change filter.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Repair — 4-ton system oversized
- HVAC
- $293HVACPerformed diagnostic service call on AC system: found soiled air filter and missing outdoor disconnect pull switch; replaced pull switch and air filter; noted system is oversized at 4-ton for a 1,500 sq ft home and recommended replacement with a properly sized 2.5-ton system and 60,000 BTU furnace.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Sewer
This record, dated August 1, 2025, documents HVAC and Sewer at 9525 Stansberry Avenue, St. Louis, MO 63134.
- HVAC,
- Sewer
Only original contributor can modify this entry
Create an account to manage your contributions over time
Recorded Aug 2025
This record, dated August 1, 2025, documents Appraisal at 9525 Stansberry Avenue, St. Louis, MO 63134.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,