Complete public upload archive

Property records for 9616 Bent Pine Drive, St. Louis, MO 63126

All 5 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 5.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Installation — 25/5 dual run capacitor installed

  • HVAC

On July 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9616 Bent Pine Drive, St. Louis, MO 63126.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$449

    Performed an overtime residential diagnostic and installed a 25/5 dual run capacitor.

  • HVACWork status not resolved

    Photograph shows an outdoor central cooling air conditioner condenser unit (Central Environmental Systems, Model H1DA018S06A, Serial ENYM182815) with a data plate indicating R22 refrigerant, 208/230V 1PH 60Hz supply, and a manufacture date of December 1991; the unit is surrounded by rocks and debris.

  • HVACWork status not resolved

    two electrical disconnect boxes with conduit are mounted on the wall above the units

  • HVACWork status not resolved

    Photograph shows a tan/beige vertical split-system air handler unit installed in a utility room, with flexible refrigerant lines, armored electrical conduit, and supply ductwork connected at the top; the unit sits on a raised platform base.

  • HVACWork status not resolved

    Photograph shows insulated refrigerant line set running from a white sheet-metal air handler box along the ceiling, with the pipe insulation visibly deteriorated — blackened, crumbling, and partially missing near the brass fitting connections at the lower end; flexible metallic conduit also enters the air handler box.

  • HVACWork status not resolved
Record 2Public property recordUnit A

HVAC Air Conditioner Estimate — 16 SEER 2.5-ton A/C and coil

  • HVAC

On July 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9616 Bent Pine Drive, St. Louis, MO 63126.

Record date

Available findings

  • HVACEstimate or proposed work$7,407

    Estimate for a 16 SEER 2.5-ton American Standard air conditioner and cased evaporator coil, with 30-amp disconnect, condenser pad, materials and labor.

Record 3Public property recordUnit A

HVAC System Estimate — 2.5-ton Goodman air handler + A/C

  • HVAC

On July 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9616 Bent Pine Drive, St. Louis, MO 63126.

Record date

Available findings

  • HVACEstimate or proposed work$8,653

    Estimate for a 2.5-ton 14 SEER Goodman system including air handler, 15-KW heat kit, condenser, pads, install materials, 30-amp disconnect, and apprentice and journeyman labor; option status expired.

Record 4Public property recordUnit A

HVAC Estimate — 2.5-ton 14 SEER A/C and coil

  • HVAC

On July 5, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9616 Bent Pine Drive, St. Louis, MO 63126.

Record date

Available findings

  • HVACEstimate or proposed work$6,994

    Estimate for a 14 SEER 2.5-ton air conditioner and cased evaporator coil, with condenser pad, 30-amp disconnect, materials and labor.

Record 5Public property record

HVAC Refrigerant Charge — 1.5 lb R22 refrigerant charge

  • HVAC

On July 6, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9616 Bent Pine Drive, St. Louis, MO 63126.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$120

    Charged system with 1.5 pounds of R22 refrigerant.

  • HVACWork status not resolved

    Photograph shows a CPS digital refrigerant scale displaying a reading of 1 lb 11.75 oz, placed on a gravel surface next to a refrigerant recovery/charging case with a red hose visible.

  • HVACWork status not resolved

    Photograph shows an HVAC evaporator coil with heavy accumulation of dust, lint, and debris across the fin surface, and significant ice/frost buildup along the bottom edge of the coil; a copper refrigerant line is visible at the lower right.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge lying on gravel with yellow, red, and blue refrigerant hoses connected, displaying pressure readings in psig and psi along with temperature and superheat/subcooling values on its LCD screen.