HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
On March 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9740 Lanier Drive, St. Louis, MO 63136.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$219
Performed a residential diagnostic service with residential labor at the service address.
- HVACWork status not resolved
Photograph shows a heavily soiled pleated HVAC air filter with dark gray/brown debris accumulation across the entire filter media surface, indicating the filter is well past its service life and requires replacement.
- HVACWork status not resolved
Photograph shows an aged HVAC air handler or furnace unit with multiple foil-tape (Shurtape AF 099 / 181A-P) patches applied to the sheet metal casing, corroded and rusted metal flue/duct connections on the right side, and electrical wiring passing through the unit housing, located in a brick-walled mechanical space.
- HVACWork status not resolved
Photograph shows a furnace unit with a louvered top panel, a sheet metal plenum above with heavily deteriorated and torn foil duct tape, a round flue/exhaust pipe, and an orange service sticker on the plenum; loose wiring and debris are visible on the floor.
- HVACWork status not resolved
Photograph shows HVAC ductwork in a crawl space or confined utility area with severely torn and deteriorated foil-faced insulation wrap hanging loose from the duct body in multiple locations, alongside conduit or piping and darkened wood framing members.
- HVACWork status not resolved
Photograph shows the interior wiring compartment of an HVAC unit with a large, heavily soiled and disorganized bundle of multi-colored wires, a loose yellow wire nut resting on the cabinet floor, and significant dirt and debris accumulation throughout the compartment; a control board with indicator lights is partially visible in the background.
- HVACWork status not resolved
Photograph shows a large void in a wooden structural member with severely deteriorated, crumbling, fibrous wood consistent in appearance with wood-destroying insect activity; metal pipes are visible passing through the damaged area.
- HVACWork status not resolved
Photograph shows a yellow SPK2 digital thermometer displaying a surface temperature reading of 46.1°F, resting on a concrete or subfloor surface near foil-faced barrier material.
- UnclassifiedWork status not resolved
description section is collapsed and trade/system details are not visible
- HVACWork status not resolved
Photograph shows a wall penetration with a flexible metallic pipe/conduit secured by a metal bracket, surrounded by makeshift foil/duct tape patching; the upper pipe or conduit has severely deteriorated, shredded blackened insulation wrapping.
- HVACWork status not resolved
Photograph shows a heavily dust-covered, warped, and partially detached sheet metal HVAC cabinet panel with visible deterioration, torn foil tape at the base, and flexible ductwork exposed at the top.