HVAC Service Call — Frozen unit, low on R22; recharged
HVAC
On May 30, 2025, ASSURED HEATING AND COOLING documented HVAC at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$520
Service call on a frozen unit with a very dirty outdoor unit; cleaned the system, found it low on R22, added R22 by the pound with stop leak, inspected system function, and supplied a 16x22x1 filter.
Record 2·Public property record
HVAC Service Invoice — No-charge HVAC service visit
HVAC
On June 23, 2025, ASSURED HEATING AND COOLING documented HVAC at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Available findings
HVACCompleted work
Service visit performed at 9743 Edgefield Drive with a single charge unit line and no charge.
Record 3·Public property record
HVAC Condenser and Coil Replacement — 2-ton R410A condenser
HVAC
On June 25, 2025, ASSURED HEATING AND COOLING documented HVAC at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$4,300
Work performed: Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing); Equipment Warranty; Payment Terms; Terms and Conditions.
Record 4·Public property record
HVAC Service Call — System working as intended, readings in spec
HVAC
On June 27, 2025, ASSURED HEATING AND COOLING documented HVAC at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Available findings
HVACCompleted work
Service call for a reported non-working new system; on arrival the system was found working as intended, with airflow, charge and temperature readings all within specs.
HVACWork status not resolved
Photograph shows a Fluke 116 True RMS Multimeter displaying a reading of 69.6°F, held against a dark-colored electrical enclosure or panel in what appears to be a basement or utility area with concrete block walls visible.
HVACWork status not resolved
Photograph shows a Fluke 116 True RMS Multimeter strapped to a sheet metal HVAC duct, displaying a reading of 44.7, with a duct register visible in the background and orange probe wire connected.
HVACWork status not resolved
Photograph shows an Emerson wall-mounted thermostat displaying a room temperature of 73°F, set point of 60°F, with the system in Cool On mode and fan set to Auto.
HVACWork status not resolved
Photograph shows a Fluke 115 True RMS Multimeter reading 49.8°F positioned in front of a wall-mounted HVAC louvered vent register; the vent register appears dusty with debris visible along its lower edge.
Record 5·Public property record
Plumbing Flange Repair Invoice — Iron flange replaced with PVC
Plumbing
On March 4, 2024, Drain Clean USA, LLC documented Plumbing at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Available findings
Plumbing$1,100
Cut and removed iron flange, replaced with PVC flange and closet bend; removed and installed new toilet with wax ring and bolts — operational with no leaks.
Record 6·Public property record
Plumbing Drain Cleaning Invoice — main line blockage cleared
Plumbing
On March 1, 2025, Drain Clean USA, LLC documented Plumbing at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Available findings
Plumbing$407
Cabled main line at yard, used camera and machine to open line; 30-day warranty provided.
On July 1, 2025, Arch Air Services documented HVAC at 9743 Edgefield Drive, St. Louis, MO 63136.
Record date
Available findings
HVAC$372
Diagnosed low blower and freezing coil caused by improper low-voltage furnace wiring; rewired furnace, balanced overcharged refrigerant, and opened two shut dampers — system restored to proper operation.
Record 8·Public property record
Document
HVAC
Sewer
This record documents HVAC and Sewer at 9743 Edgefield Drive, St. Louis, MO 63136.
Record description
Basement foundation so sewer issues arent as concerning to me opposed to if it was a slab