Record 1Public property record

HVAC Service Call — Clogged filter overheated furnace; flue leaking

  • HVAC

On January 17, 2024, ASSURED HEATING AND COOLING documented HVAC at 9765 Dennis Drive, St. Louis, MO 63136.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    No heat service call: clogged filter caused furnace to overheat; filter replaced and system inspected, all systems working as expected, and a roof or chimney company is needed to redo the leaking flue system.

  • HVACWork status not resolved

    Photograph shows a York furnace (EnergyGuide 80.0 AFUE) with a heavily soiled HDX 14x25x1 FPR-5 air filter removed and leaning against the unit; the filter media is densely packed with dust and debris, and dark staining is visible on the floor at the furnace base.

  • HVACWork status not resolved

    Photograph shows a gas furnace with an EnergyGuide label rating 80.0 AFUE, internal wiring and gas valve components exposed at the top, and an HDX 14x25x1 FPR 5 air filter partially removed from the bottom filter slot; handwritten markings on the cabinet indicate air flow direction and filter size.

  • HVACWork status not resolved

    Photograph shows the lower cabinet and base pan of a furnace/air handler unit with heavy rust and orange-brown corrosion on the base pan, flue elbow, and surrounding surfaces, along with a white PVC condensate drain line and a Mechanical Final Inspection Approval sticker dated 5/31/07 affixed to the unit.

  • HVACWork status not resolved

    Photograph shows the interior of a natural gas furnace with access panel removed, revealing the gas valve (switch in OFF position), inducer/draft motor assembly, wiring harness, and a U.S. Government EnergyGuide label identifying the unit as a natural gas furnace.

  • HVACWork status not resolved

    a white PVC condensate drain line and a Mechanical Final Inspection approval sticker are also visible

  • HVACWork status not resolved

    Photograph shows a UL-listed chimney flue liner/collar with heavy rust and corrosion at the connection point, deteriorated and torn foil-faced insulation wrap on the adjacent flexible duct, and visible staining and damage at the ceiling penetration where the flue exits upward.