- HVAC · Natural gas furnace and coil replaced with sheet metal work · Jul 2024
- HVAC · Gas shutoff, flue, electrical, and refrigerant added during furnace install · Jul 2024
- HVAC · Furnace and coil replacement proposed with sheet metal work · Aug 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 9770 Scottdale Drive, St. Louis, MO 63136, dated in August 2025. The amount summary includes $10,202.28 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Installation — 80% gas furnace + two-ton coil installed
- HVAC
Built from Housecall Pro data
- $4,519HVACInstalled an 80% natural gas furnace and cased/uncased two-ton coil, including sheet metal work, gas shut off and pipe, electrical switch and power, flue work, and added 4 lbs of 410A refrigerant.
- HVACPhotograph shows a gray air handler/furnace unit installed within a new wood-framed stud wall enclosure in a basement, with a sheet metal supply plenum above, copper refrigerant lines, a round metal flue pipe, flexible condensate drain tubing, and loose electrical wiring visible; surrounding framing is unfinished.
- HVACPhotograph shows a gray vertical HVAC unit (furnace or air handler) installed within a wood-framed mechanical chase, connected to a sheet metal plenum and ductwork above, with copper refrigerant lines visible to the right.
- HVACPhotograph shows sheet metal HVAC ductwork plenum/transition box with mastic-sealed joints mounted above wood-framed wall cavity, with a pleated air filter in a metal frame leaning against the lower ductwork, and a green-painted structural column visible in the background, in an unfinished construction area.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — Rheem 80% furnace + 2.5-ton coil
- HVAC
Built from Housecall Pro data
- $5,683HVACWork performed: 80% 75,000 BTU 2.5 Ton R410A (We purpose to install the following equipment in your home); Furnace / Coil Only Install Description (This quote will include the following, sheet metal work to adapt to new); Equipment Warranty; Payment Terms; Terms and Conditions.
- HVACPhotograph shows an attic-installed air handler unit with insulated refrigerant lines (black foam-wrapped copper tubing with blue fittings) and sheet metal ductwork/plenum visible in a confined attic space.
- HVACPhotograph shows a Sime-branded gas furnace with an attached coil/air handler section connected to overhead sheet-metal supply ductwork, located in an unfinished basement mechanical room; a yellow HVAC service sticker is visible on the adjacent structural post.
- HVACPhotograph shows a gray metal air handler unit installed within exposed wood stud framing in an unfinished basement, with sheet metal ductwork above, a flexible flue/duct pipe, copper refrigerant line, and black gas piping with shutoff valve fittings visible.
- HVACPhotograph shows large sheet metal HVAC ductwork (plenum/trunk with multiple branch takeoffs) installed within a wood-framed basement or utility space; ductwork appears uninsulated and in generally intact condition.
- HVACPhotograph shows a gas furnace installed in an unfinished basement mechanical area, connected to sheet metal supply ductwork and a flue vent pipe; the unit appears to be in place with a condensate drain line visible.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.