HVAC Maintenance — Dual run capacitor supplied
- HVAC
On October 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 9812 Baltimore Avenue, Overland, MO 63114.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$349
Trip fee charged and a dual run capacitor supplied during the service call.
- HVACWork status not resolved
Photograph shows the data plate of an outdoor HVAC condenser unit, model BA14NA030-A, serial 1620X50996, using R-410A refrigerant, rated 208-230V/1PH/60Hz, manufactured April 2020, with a minimum circuit ampacity of 16.8A and max fuse of 25A.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge set displaying R410A refrigerant readings: superheat (SH) 6.9°F, subcooling (SC) 7.5°F, low-side pressure 116.2 psig, and high-side pressure 179.5 psig.
- HVACWork status not resolved