9844 Ravensbrook Drive
Across 4 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 4 documented records
Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · Air conditioner replaced with new Lennox Elite unit · Apr 2026
- HVAC · AC installation included condenser pad, disconnect, and relocation · Apr 2026
- HVAC · Furnace serviced; 2002 unit found in normal working condition · Oct 2026
- HVAC · Heat exchanger showed signs of thermal stress at service · Oct 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 9844 Ravensbrook Drive, St. Louis, MO 63123, dated from March 2026 through October 2026. The amount summary includes $7,322.88 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC In-Home Consultation — In home consultation, no charge
- HVAC
Built from Housecall Pro data
- HVACIn home consultation was provided at the service address.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 2.5-ton Lennox Elite A/C and coil
- HVAC
Built from Housecall Pro data
- $7,323HVACSupplied a 2.5-ton Lennox Elite Series air conditioner and 2.5-ton cased coil, with condenser pad, 30-amp fused disconnect, install materials and journeyman and apprentice labor; AC relocation included.
- HVACPhotograph shows the data plate of an HVAC refrigerant evaporator/heat pump coil section, model CK40CT-36B-71, serial 1526A28613, manufactured 01/2026, factory-installed TXV suitable for R-454B refrigerant, with a maximum allowable pressure of 640 PSIG (4413 KPA).
- HVACPhotograph shows a digital thermometer (DFP450W) reading 48.2°F placed on metallic-taped ductwork labeled 181A-P / 181B.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Maintenance — Heat exchanger signs of thermal stress
- HVAC
- HVACPerformed routine heating maintenance: cleaned ignition components, cycled furnace and verified 50° temperature rise, replaced air filter with 20/25/1" Merv 7, inspected heat exchanger (signs of thermal stress present), and performed humidifier maintenance including pad replacement; furnace is from 2002 and in normal working condition at this time.