Hi, I'm 100 Florwood Court. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
100 Florwood Court
St. Louis, MO 6313538.7461°N, 90.2817°W
1Event
Contributed by:1 contributor
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Whole-home inspection found property in generally great condition · Oct 2026
- Electrical · Smoke detector missing in basement; GFCI outlet inoperable; ungrounded outlets noted · Oct 2026
- Roof · Roof shingles estimated about one year old and satisfactory · Oct 2026
- Plumbing · Water heater expansion tank needs securing; seismic straps absent · Oct 2026
- Pest · Wood destroying insect inspection performed on home and attached garage · Oct 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Oct 2026
Latest documented event: Oct 2026
First added to Fresh House: Oct 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 100 Florwood Court, St. Louis, MO 63135, dated in October 2026.
Home Inspection
Home Inspection Document
Inspected Oct 14, 2026Uploaded Oct 14, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 100 Florwood Court, St. Louis, MO 63135.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
Contributor
worked on or inspected it- PestWood destroying insect inspection of SFR/attached garage at 100 Florwood Court; the form's Section II and III boxes are not legibly marked, and the report states it is not a guarantee or warranty against latent or future infestations.
- Home InspectionWhole-home inspection of single-family property found home in generally great condition with no structural issues; deficiencies noted across electrical, roofing, plumbing, and windows systems.
- Electricalsmoke detector missing in basement near gas appliances main-floor bathroom GFCI outlet inoperable and needs replacement 2-prong ungrounded outlets present
- FoundationCinderblock foundation in satisfactory condition; missing mortar should be replaced as preventive maintenance.
- Plumbingwater heater expansion tank requires securing with coated metal straps; seismic straps not present
- RoofArchitectural shingle roof estimated 1 year old and satisfactory; tree limbs hanging over roof require trimming and gutters have leaves and debris that need removal.
- WindowsDamaged window trim over the kitchen window requires repair.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented