HVAC Service Invoice — No-charge HVAC service visit
- HVAC
On August 14, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 10083 Buffton Drive, St. Louis, MO 63123.
- Record date
Available findings
- HVACCompleted work
HVAC service visit at 10083 Buffton Drive on August 14, 2026 with no service lines itemized.
- HVACWork status not resolved
Photograph shows a Rheem Category I forced-air natural gas furnace (Model R801SA075317MSA, Serial W181752021, manufactured 05/2017) with a maximum input rating of 75,000 BTU/hr, installed in what appears to be a mechanical space.
- HVACWork status not resolved
Photograph shows the data plate of a Rheem outdoor condensing unit, Model RA1336AJ1NA, Serial W181720920, manufactured 05/2017, rated 208/230V single-phase, R410A refrigerant, factory charge 86 oz.
- HVACWork status not resolved
Photograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 139.6 psig, liquid pressure 314.2 psig, actual superheat 12.1°F, actual subcooling 9.4°F; air-side diagnostics indicate supply dry bulb 62.5°F vs. target 63.0°F with adequate airflow across the evaporator coil noted.
- HVACWork status not resolved
Photograph shows a close-up of a metal louvered HVAC vent register with visible dust accumulation and light debris on the grille face and louver surfaces.
- HVACWork status not resolved
Photograph shows a close-up of a metal louvered grille, consistent with an HVAC unit exterior panel, with visible fibrous debris (lint or hair) accumulated in the louver openings, particularly on the right side.
- HVACWork status not resolved
Photograph shows a Fluke 116 True RMS Multimeter displaying a capacitance reading of 22.5 μF, being tested against what appears to be an outdoor HVAC condenser unit.
- HVACWork status not resolved
Photograph shows a close-up of a white/light-gray louvered metal panel, consistent with the exterior casing of an outdoor HVAC condensing unit, with rows of stamped arch-shaped vent openings and minor surface debris visible.
- HVACWork status not resolved
Photograph shows the interior of an outdoor HVAC condenser unit with a round dual-run capacitor mounted on a bracket and a contactor relay, connected by multiple colored wires (yellow, orange, brown, purple); dirt and debris are present on the bottom panel.
- HVACWork status not resolved
Photograph shows a Fluke 116 True RMS Multimeter displaying a capacitance reading of 4.70 μF, being tested at an outdoor HVAC condenser unit visible in the background.
- HVACWork status not resolved
Photograph shows a close-up of an HVAC air register or return grille with heavy accumulation of dust and debris coating the louvers and frame.
- HVACWork status not resolved
Photograph shows a removed CSC dual-run capacitor (45+5μF, 370VAC, part 43-101665-41) held in front of an HVAC unit's electrical compartment, where a replacement capacitor is already mounted alongside a contactor and associated wiring.
- HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter displaying a reading of 63 amps AC, being used near a concrete wall in what appears to be a basement or utility area.