Hi, I'm 10083 Buffton Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
10083 Buffton Drive
St. Louis, MO 6312338.5384°N, 90.3387°W
1Event
Contributed by:1 contributor
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · HVAC system received a service visit in August 2026 · Aug 2026
- HVAC · Gas furnace manufactured May 2017 is present at the property · 2026
- HVAC · Outdoor air conditioner unit manufactured May 2017 is present · 2026
- HVAC · A capacitor is visible inside the outdoor condenser unit · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First added to Fresh House: Nov 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 10083 Buffton Drive, St. Louis, MO 63123.
HVAC
HVAC Service Invoice — No-charge HVAC service visit
Document dated Aug 14, 2026Uploaded Nov 8, 202613 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 10083 Buffton Drive, St. Louis, MO 63123.
Scope
- HVAC
Built from Housecall Pro data
- HVACHVAC service visit at 10083 Buffton Drive on August 14, 2026 with no service lines itemized.
- HVACPhotograph shows a Rheem Category I forced-air natural gas furnace (Model R801SA075317MSA, Serial W181752021, manufactured 05/2017) with a maximum input rating of 75,000 BTU/hr, installed in what appears to be a mechanical space.
- HVACPhotograph shows the data plate of a Rheem outdoor condensing unit, Model RA1336AJ1NA, Serial W181720920, manufactured 05/2017, rated 208/230V single-phase, R410A refrigerant, factory charge 86 oz.
- HVACPhotograph shows Fieldpiece app refrigerant measurements for R-410A system: suction pressure 139.6 psig, liquid pressure 314.2 psig, actual superheat 12.1°F, actual subcooling 9.4°F; air-side diagnostics indicate supply dry bulb 62.5°F vs. target 63.0°F with adequate airflow across the evaporator coil noted.
- HVACPhotograph shows a close-up of a metal louvered HVAC vent register with visible dust accumulation and light debris on the grille face and louver surfaces.
- HVACPhotograph shows a close-up of a metal louvered grille, consistent with an HVAC unit exterior panel, with visible fibrous debris (lint or hair) accumulated in the louver openings, particularly on the right side.
- HVACPhotograph shows a Fluke 116 True RMS Multimeter displaying a capacitance reading of 22.5 μF, being tested against what appears to be an outdoor HVAC condenser unit.
- HVACPhotograph shows a close-up of a white/light-gray louvered metal panel, consistent with the exterior casing of an outdoor HVAC condensing unit, with rows of stamped arch-shaped vent openings and minor surface debris visible.
- HVACPhotograph shows the interior of an outdoor HVAC condenser unit with a round dual-run capacitor mounted on a bracket and a contactor relay, connected by multiple colored wires (yellow, orange, brown, purple); dirt and debris are present on the bottom panel.
- HVACPhotograph shows a Fluke 116 True RMS Multimeter displaying a capacitance reading of 4.70 μF, being tested at an outdoor HVAC condenser unit visible in the background.
- HVACPhotograph shows a close-up of an HVAC air register or return grille with heavy accumulation of dust and debris coating the louvers and frame.
- HVACPhotograph shows a removed CSC dual-run capacitor (45+5μF, 370VAC, part 43-101665-41) held in front of an HVAC unit's electrical compartment, where a replacement capacitor is already mounted alongside a contactor and associated wiring.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter displaying a reading of 63 amps AC, being used near a concrete wall in what appears to be a basement or utility area.
HVAC
HVAC
HVAC
HVAC+8
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
HVAC
✓ documentedHome Inspection
undocumentedRoof
undocumentedPlumbing
undocumentedSewer
undocumentedFoundation
undocumentedMold
undocumentedElectrical
undocumentedPest
undocumentedRadon
undocumentedAppraisals
undocumentedWindows
undocumented