- HVAC · Dual run capacitor supplied for the air conditioner · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 10104 Grant Meadow Lane, St. Louis, MO 63123. The amount summary includes $349 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Capacitor Service — Dual run capacitor supplied
- HVAC
Built from Housecall Pro data
- $349HVACSupplied a dual run capacitor and charged a trip fee for the service visit.
- HVACPhotograph shows a dual run capacitor rated 45/7.5μF ±6% at 440VAC, 50/60Hz, installed inside an HVAC unit alongside a contactor; notable dust and debris accumulation is visible throughout the cabinet.
- HVACPhotograph shows an outdoor air conditioning condenser unit with a manufacturer data plate indicating model NXA648GKA100, serial E173001082, R-410A refrigerant, 208/230V power supply, and a manufacture date of July 2017; label also states 'Installation Prohibited in Southwest.'
- HVACPhotograph shows a Fluke 116 True RMS Multimeter with red test leads attached to an HVAC condenser unit, with a disconnect box visible to the right and condenser coil fins to the left.
- HVACPhotograph shows a red digital instant-read thermometer with its probe inserted into a galvanized sheet-metal HVAC duct, with the display reading 135 (degrees).
- HVACPhotograph shows a Testo digital manifold gauge connected to an outdoor AC condenser, displaying R410A refrigerant readings: low-side pressure 123.7 psi, high-side pressure 185.7 psi, suction temp 42.3°F, discharge temp 64.9°F, T1 32.0°F, T2 49.7°F, and subcooling 15.2°F.
- HVACPhotograph shows a Fluke 323 True RMS clamp meter clamped around outdoor HVAC unit wiring, displaying approximately 25 amps AC current draw, with multiple colored conductors visible near the unit.
- HVACPhotograph shows a Fluke True RMS multimeter with red test leads being used to take an electrical measurement at what appears to be a gray metal electrical enclosure or disconnect, with a metal condenser cage visible to the left.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter reading 9.4 A AC current, being used to test an HVAC air handler unit; a green LED status indicator is visible on the unit's control board in the background.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.