Complete public upload archive

Property records for 10254 Valley Drive, St. Louis, MO 63137

All 4 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 4.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

Document

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On March 10, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • Roof

    Roof covering is 3-tab shingle and roll roofing estimated at 10 years old and rated satisfactory; ceiling damage in the middle bedroom is attributed to rain water leaking in during hard rains, indicating a potential roof leak; no gutters or downspouts are present.

  • HVAC

    Central split system with DuCane forced-air gas furnace (manufactured 2021) and Coleman 2-ton electric AC condenser (manufactured 2022) both appear functional and rated satisfactory; kitchen exhaust fan for gas range is absent and installation is recommended.

  • Plumbing

    Copper supply pipes and PVC waste pipes are satisfactory; General Electric 40-gallon natural gas water heater manufactured in 2007 appears functional but is approximately 16 years old.

  • Foundation

    Poured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls and floor rated satisfactory.

  • Pest

    No termite damage or presence was observed; termite treatment appears to have been previously performed.

  • Electrical

    Multiple electrical deficiencies noted: GFI outlet at carport is inoperable; bathroom GFI outlet will not reset and needs replacement; kitchen GFI outlet has hot and ground wires reversed and needs rewiring; electrical outlets near the utility area are inoperable despite breakers being on; smoke detectors are missing throughout the home including near basement gas appliances.

  • Windows

    Exterior windows include vinyl, aluminum, and steel-framed basement windows, all rated satisfactory with no deficiencies noted.

  • Unclassified

    Exterior trim damage on front corners of home and deteriorated hardboard siding over the front porch require repair.

  • Home Inspection

    Whole-home inspection of 10redacted identified multiple electrical deficiencies, a rain-water ceiling leak, exterior siding/trim damage, missing smoke detectors, and an aging water heater, with no structural deficiencies observed.

Record 2Public property record

HVAC Diagnostic Leak Search — Evaporator coil leak

  • HVAC

On May 22, 2025, Arch Air Services documented HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • HVAC$278

    Performed AC diagnostic (power tripped to unit, pressures nearly empty of 410a) and refrigerant leak search; leak found in indoor evaporator coil with coil replacement recommended.

Record 3Public property record

HVAC Evaporator Coil Installation — TRANE 2-ton evaporator coil

  • HVAC

On June 3, 2025, Arch Air Services documented HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • HVAC$1,785

    Installed TRANE 2-ton evaporator coil (410a refrigerant approved, 17.5") including reconnection to copper refrigerant lines, new liquid line filter drier, new sheet metal plenum transition, new condensate drain system, refrigerant top-off (6 lbs of 410a), mastic sealant, and removal/haul away of existing air conditioning system.

Record 4Public property record

Inspection

  • HVAC

This record documents HVAC at 10254 Valley Drive, St. Louis, MO 63137.

View 10254 Valley Drive, St. Louis, MO 63137 on Fresh House