Record 1Public property record

HVAC Service Call — Compressor shorted to ground

  • HVAC

On May 21, 2025, ASSURED HEATING AND COOLING documented HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • HVACCompleted work$154

    Normal hours service call: outdoor unit found not working properly, compressor found shorted to ground with internal windings touching; replacement quoted at roughly 3000 to 3700, and the microchannel coil is noted as likely to cause future failures.

Record 2Public property record

HVAC Condensing Unit Estimate — 2-ton condensing unit and coil

  • HVAC

On May 21, 2025, ASSURED HEATING AND COOLING documented HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • HVACEstimate or proposed work$4,623

    Estimate for installing a 2 Ton 13 SEER R410A condensing unit with TXV cased coil, including fused disconnect, electrical whip, pad, sheet metal adaptation, and line set flush and pressure test.

Record 3Public property record

Document

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On March 10, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • Electrical

    Multiple electrical deficiencies noted: GFI outlet at carport is inoperable; bathroom GFI outlet will not reset and needs replacement; kitchen GFI outlet has hot and ground wires reversed and needs rewiring; electrical outlets near the utility area are inoperable despite breakers being on; smoke detectors are missing throughout the home including near basement gas appliances.

  • Foundation

    Poured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls and floor rated satisfactory.

  • Home Inspection

    Whole-home inspection of 10redacted identified multiple electrical deficiencies, a rain-water ceiling leak, exterior siding/trim damage, missing smoke detectors, and an aging water heater, with no structural deficiencies observed.

  • HVAC

    Central split system with DuCane forced-air gas furnace (manufactured 2021) and Coleman 2-ton electric AC condenser (manufactured 2022) both appear functional and rated satisfactory; kitchen exhaust fan for gas range is absent and installation is recommended.

  • Pest

    No termite damage or presence was observed; termite treatment appears to have been previously performed.

  • Plumbing

    Copper supply pipes and PVC waste pipes are satisfactory; General Electric 40-gallon natural gas water heater manufactured in 2007 appears functional but is approximately 16 years old.

  • Roof

    Roof covering is 3-tab shingle and roll roofing estimated at 10 years old and rated satisfactory; ceiling damage in the middle bedroom is attributed to rain water leaking in during hard rains, indicating a potential roof leak; no gutters or downspouts are present.

  • Unclassified

    Exterior trim damage on front corners of home and deteriorated hardboard siding over the front porch require repair.

  • Windows

    Exterior windows include vinyl, aluminum, and steel-framed basement windows, all rated satisfactory with no deficiencies noted.

Record 4Public property record

HVAC Diagnostic Leak Search — Evaporator coil leak

  • HVAC

On May 22, 2025, Arch Air Services documented HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • HVAC$278

    Performed AC diagnostic (power tripped to unit, pressures nearly empty of 410a) and refrigerant leak search; leak found in indoor evaporator coil with coil replacement recommended.

Record 5Public property record

HVAC Evaporator Coil Installation — TRANE 2-ton evaporator coil

  • HVAC

On June 3, 2025, Arch Air Services documented HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Record date

Available findings

  • HVAC$1,785

    Installed TRANE 2-ton evaporator coil (410a refrigerant approved, 17.5") including reconnection to copper refrigerant lines, new liquid line filter drier, new sheet metal plenum transition, new condensate drain system, refrigerant top-off (6 lbs of 410a), mastic sealant, and removal/haul away of existing air conditioning system.

Record 6Public property record

Inspection

  • HVAC

This record documents HVAC at 10254 Valley Drive, St. Louis, MO 63137.