← MAP

10254 Valley Drive

St. Louis, MO 6313738.7528°N, 90.2089°W
6Events
Contributed by:4 contributors
$6.8kDocumented amounts
SOURCE-BACKED RECORDS

Across 6 records on this home

Completed work

Invoices and paid receipts

None documented yet

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

$6.8k

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 6 documented records

Fresh House Property Summary

Highlights selected from 6 documented records for this property.

  • HVAC
    HVAC · Evaporator coil replaced with new plenum and drain system · 2025
  • HVAC
    HVAC · AC diagnostic found refrigerant nearly empty and coil leaking · 2025
  • HVAC
    HVAC · Outdoor compressor found shorted to ground and not working · May 2025
  • Electrical
    Electrical · Multiple inoperable and miswired GFI outlets found throughout home · 2023
  • Plumbing
    Plumbing · Water heater was approximately 16 years old at inspection · 2023
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 10254 Valley Drive. I only speak from this property's source-backed records — 6 documents from 4 contributors. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

6 documented events
Contributed by: 4 contributors
First documented event: Mar 2023
Latest documented event: Jun 2025
First added to Fresh House: Feb 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 6 documented records for 10254 Valley Drive, St. Louis, MO 63137, dated from March 2023 through June 2025. The amount summary includes $4,777 in estimates, $2,063 with completion status not stated; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Service Call — Compressor shorted to ground

Document dated May 21, 2025Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10254 Valley Drive, St. Louis, MO 63137.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $154
  • HVACNormal hours service call: outdoor unit found not working properly, compressor found shorted to ground with internal windings touching; replacement quoted at roughly 3000 to 3700, and the microchannel coil is noted as likely to cause future failures.
    $154

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Condensing Unit Estimate — 2-ton condensing unit and coil

Document dated May 21, 2025Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10254 Valley Drive, St. Louis, MO 63137.
Scope
  • HVAC
Contributor
worked on or inspected it

Option: Option #1 $4,623 (declined)

Built from Housecall Pro data

Estimated value on this timeline entry: $4,623
  • HVACEstimate for installing a 2 Ton 13 SEER R410A condensing unit with TXV cased coil, including fused disconnect, electrical whip, pad, sheet metal adaptation, and line set flush and pressure test.
    $4,623
warrantyfive-year / ten-year / twenty-yearFrom estimateView details
Documented warrantyfrom estimate · May 21, 2025HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “manufacturer five-year parts warranty”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

  • labor
    · source

    “Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

DOCUMENTED

Home Inspection

Inspected Mar 10, 2023Uploaded Apr 28, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 10254 Valley Drive, St. Louis, MO 63137.
Scope
  • Electrical,
  • Foundation,
  • HVAC,
  • Home Inspection,
  • Pest,
  • Plumbing,
  • Roof,
  • Windows
Contributor
worked on or inspected it
  • ElectricalMultiple electrical deficiencies noted: GFI outlet at carport is inoperable; bathroom GFI outlet will not reset and needs replacement; kitchen GFI outlet has hot and ground wires reversed and needs rewiring; electrical outlets near the utility area are inoperable despite breakers being on; smoke detectors are missing throughout the home including near basement gas appliances.
  • FoundationPoured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls and floor rated satisfactory.
  • HVACCentral split system with DuCane forced-air gas furnace (manufactured 2021) and Coleman 2-ton electric AC condenser (manufactured 2022) both appear functional and rated satisfactory; kitchen exhaust fan for gas range is absent and installation is recommended.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Diagnostic Leak Search — Evaporator coil leak

Document dated May 22, 2025Uploaded Apr 28, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
Arch Air Servicesdocumented HVAC at 10254 Valley Drive, St. Louis, MO 63137.
Scope
  • HVAC
Contributor
worked on or inspected it
Documented amount on this timeline entry: $278
  • HVACPerformed AC diagnostic (power tripped to unit, pressures nearly empty of 410a) and refrigerant leak search; leak found in indoor evaporator coil with coil replacement recommended.
    $278

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Evaporator Coil Installation — TRANE 2-ton evaporator coil

Document dated Jun 3, 2025Uploaded Apr 28, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
Arch Air Servicesdocumented HVAC at 10254 Valley Drive, St. Louis, MO 63137.
Scope
  • HVAC
Contributor
worked on or inspected it
Documented amount on this timeline entry: $1,785
  • HVACInstalled TRANE 2-ton evaporator coil (410a refrigerant approved, 17.5") including reconnection to copper refrigerant lines, new liquid line filter drier, new sheet metal plenum transition, new condensate drain system, refrigerant top-off (6 lbs of 410a), mastic sealant, and removal/haul away of existing air conditioning system.
    $1,785

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Document

Uploaded Feb 19, 2026
Community-uploaded

This record documents HVAC at 10254 Valley Drive, St. Louis, MO 63137.

Scope
  • HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Home Inspection
✓ documented
Roof
✓ documented
Plumbing
✓ documented
Foundation
✓ documented
Electrical
✓ documented
HVAC
✓ documented
Pest
✓ documented
Windows
✓ documented
Sewer
undocumented
Mold
undocumented
Radon
undocumented
Appraisals
undocumented

Nearby homes with documented history