Fresh House Property Summary
Generated from 4 documented records on this property page.
- Electrical · Multiple safety issues: bad wiring, broken outlets, missing smoke detectors · 2023
- HVAC · AC evaporator coil replaced due to refrigerant leak · 2025
- Foundation · Basement foundation inspected, no moisture or structural issues found · 2023
- Roof · Roof leaks into bedroom during heavy rain, no gutters present · 2023
- Plumbing · Water heater is 16 years old and may need replacement soon · 2023
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
- Home InspectionWhole-home inspection of 10254 Valley Dr, St Louis, MO 63137 identified multiple electrical deficiencies, a rain-water ceiling leak, exterior siding/trim damage, missing smoke detectors, and an aging water heater, with no structural deficiencies observed.
- RoofRoof covering is 3-tab shingle and roll roofing estimated at 10 years old and rated satisfactory; ceiling damage in the middle bedroom is attributed to rain water leaking in during hard rains, indicating a potential roof leak; no gutters or downspouts are present.
- HVACCentral split system with DuCane forced-air gas furnace (manufactured 2021) and Coleman 2-ton electric AC condenser (manufactured 2022) both appear functional and rated satisfactory; kitchen exhaust fan for gas range is absent and installation is recommended.
- PlumbingCopper supply pipes and PVC waste pipes are satisfactory; General Electric 40-gallon natural gas water heater manufactured in 2007 appears functional but is approximately 16 years old.
- FoundationPoured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls and floor rated satisfactory.
- PestNo termite damage or presence was observed; termite treatment appears to have been previously performed.
- UnclassifiedExterior trim damage on front corners of home and deteriorated hardboard siding over the front porch require repair.
- ElectricalMultiple electrical deficiencies noted: GFI outlet at carport is inoperable; bathroom GFI outlet will not reset and needs replacement; kitchen GFI outlet has hot and ground wires reversed and needs rewiring; electrical outlets near the utility area are inoperable despite breakers being on; smoke detectors are missing throughout the home including near basement gas appliances.
- WindowsExterior windows include vinyl, aluminum, and steel-framed basement windows, all rated satisfactory with no deficiencies noted.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
- $278HVACPerformed AC diagnostic (power tripped to unit, pressures nearly empty of 410a) and refrigerant leak search; leak found in indoor evaporator coil with coil replacement recommended.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
- $1,785HVACInstalled TRANE 2-ton evaporator coil (410a refrigerant approved, 17.5") including reconnection to copper refrigerant lines, new liquid line filter drier, new sheet metal plenum transition, new condensate drain system, refrigerant top-off (6 lbs of 410a), mastic sealant, and removal/haul away of existing air conditioning system.
Fresh House generated structured findings from a documented professional record.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.