- HVAC · Evaporator coil replaced with new plenum and drain system · 2025
- HVAC · AC diagnostic found refrigerant nearly empty and coil leaking · 2025
- HVAC · Outdoor compressor found shorted to ground and not working · May 2025
- Electrical · Multiple inoperable and miswired GFI outlets found throughout home · 2023
- Plumbing · Water heater was approximately 16 years old at inspection · 2023
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 6 documented records for 10254 Valley Drive, St. Louis, MO 63137, dated from March 2023 through June 2025. The amount summary includes $4,777 in estimates, $2,063 with completion status not stated; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Compressor shorted to ground
- HVAC
Built from Housecall Pro data
- $154HVACNormal hours service call: outdoor unit found not working properly, compressor found shorted to ground with internal windings touching; replacement quoted at roughly 3000 to 3700, and the microchannel coil is noted as likely to cause future failures.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condensing Unit Estimate — 2-ton condensing unit and coil
- HVAC
Option: Option #1 $4,623 (declined)
Built from Housecall Pro data
- $4,623HVACEstimate for installing a 2 Ton 13 SEER R410A condensing unit with TXV cased coil, including fused disconnect, electrical whip, pad, sheet metal adaptation, and line set flush and pressure test.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Home Inspection
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
- ElectricalMultiple electrical deficiencies noted: GFI outlet at carport is inoperable; bathroom GFI outlet will not reset and needs replacement; kitchen GFI outlet has hot and ground wires reversed and needs rewiring; electrical outlets near the utility area are inoperable despite breakers being on; smoke detectors are missing throughout the home including near basement gas appliances.
- FoundationPoured concrete foundation with basement access inspected; no moisture detected, no structural deficiencies observed, and basement walls and floor rated satisfactory.
- HVACCentral split system with DuCane forced-air gas furnace (manufactured 2021) and Coleman 2-ton electric AC condenser (manufactured 2022) both appear functional and rated satisfactory; kitchen exhaust fan for gas range is absent and installation is recommended.
- PestNo termite damage or presence was observed; termite treatment appears to have been previously performed.
- PlumbingCopper supply pipes and PVC waste pipes are satisfactory; General Electric 40-gallon natural gas water heater manufactured in 2007 appears functional but is approximately 16 years old.
- RoofRoof covering is 3-tab shingle and roll roofing estimated at 10 years old and rated satisfactory; ceiling damage in the middle bedroom is attributed to rain water leaking in during hard rains, indicating a potential roof leak; no gutters or downspouts are present.
- WindowsExterior windows include vinyl, aluminum, and steel-framed basement windows, all rated satisfactory with no deficiencies noted.
- UnclassifiedExterior trim damage on front corners of home and deteriorated hardboard siding over the front porch require repair.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Leak Search — Evaporator coil leak
- HVAC
- $278HVACPerformed AC diagnostic (power tripped to unit, pressures nearly empty of 410a) and refrigerant leak search; leak found in indoor evaporator coil with coil replacement recommended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Evaporator Coil Installation — TRANE 2-ton evaporator coil
- HVAC
- $1,785HVACInstalled TRANE 2-ton evaporator coil (410a refrigerant approved, 17.5") including reconnection to copper refrigerant lines, new liquid line filter drier, new sheet metal plenum transition, new condensate drain system, refrigerant top-off (6 lbs of 410a), mastic sealant, and removal/haul away of existing air conditioning system.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Document
This record documents HVAC at 10254 Valley Drive, St. Louis, MO 63137.