10315 Tanner Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Air conditioner serviced with R22 refrigerant recharge · Aug 2026
- HVAC · Outdoor condenser unit label shows a 2012 manufacture date · Jul 2012
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 10315 Tanner Drive, St. Louis, MO 63136. The amount summary includes $519 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Service — R22 refrigerant charge (2 lb max)
- HVAC
Built from Housecall Pro data
- $519HVACPerformed a service call with a trip fee, half an hour of residential labor, and an R22 refrigerant charge (2 lb max).
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R22 refrigerant readings: low-side pressure 59.5 psi, high-side pressure 176.8 psi, superheat 4.1°F, and subcooling 9.7°F, with the gauge resting on the ground near outdoor HVAC equipment.
- HVACPhotograph shows a Testo 557 refrigerant analyzer connected to an outdoor A/C condenser unit running R22 refrigerant, displaying suction-side temperature of 32.1°F and high-side pressure of 1732 psi; condenser coils are visibly clogged with debris.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor AC condenser unit, displaying R22 refrigerant readings of 58.7 psig / 32.7°F (low side) and 183.3 psig / 95.4°F (high side); condenser coil fins show visible debris accumulation.
- HVACPhotograph shows an outdoor HVAC condenser unit with refrigerant line set running up the exterior wall; the foam insulation on the suction line is visibly cracked, deteriorated, and falling apart along multiple sections.
- HVACPhotograph shows a basement mechanical space with a vertical round sheet metal flue/vent pipe rising through the floor assembly, horizontal duct branches forming a tee junction, and additional ductwork runs visible in the background.
- HVACPhotograph shows a mechanical room with a large sheet-metal furnace or air handler unit, overhead sheet-metal supply and return ductwork, a flue/exhaust vent pipe, black gas supply lines, and a yellow gas shutoff valve.
- HVACPhotograph shows a UEI PDT650 pocket thermometer reading 49.1°F placed on galvanized sheet metal ductwork, with round duct collars visible in the background.
- HVACPhotograph shows a heavily corroded exterior hose bib (spigot) mounted on the house siding, with multiple pipes and conduit penetrating through the siding and running down the foundation wall, surrounded by dense overgrowth of vines, cobwebs, and debris.
- HVACPhotograph shows a UEi PDT650 pocket thermometer displaying 59.5°F, positioned against galvanized sheet metal ductwork with visible screws along a seam.
- HVACPhotograph shows the exterior condenser coil fins of an outdoor HVAC unit heavily clogged with dry grass, straw, and organic debris, which can restrict airflow and reduce system efficiency.
- HVACPhotograph shows a Run Test Analysis & Conditions label affixed to a gray metal enclosure Final Charge field is blank
- HVACPhotograph shows a UEI PDT650 pocket thermometer displaying 83.4°F, resting on a dark sheet metal surface outdoors on grass, consistent with an HVAC temperature measurement.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condenser unit, displaying R22 refrigerant readings: low-side 58.7 psi and high-side 183.5 psi with a subcooling (SC) value of 13.2°F.
- UnclassifiedPhotograph shows a UEI PDT650 pocket thermometer resting on a metal frame outdoors, displaying a temperature reading of 42.6°F, surrounded by dry leaves and sparse ground vegetation.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.