HVAC Refrigerant Service — R22 refrigerant charge (2 lb max)
- HVAC
On August 24, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 10315 Tanner Drive, St. Louis, MO 63136.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$519
Performed a service call with a trip fee, half an hour of residential labor, and an R22 refrigerant charge (2 lb max).
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge displaying R22 refrigerant readings: low-side pressure 59.5 psi, high-side pressure 176.8 psi, superheat 4.1°F, and subcooling 9.7°F, with the gauge resting on the ground near outdoor HVAC equipment.
- HVACWork status not resolved
Photograph shows a Testo 557 refrigerant analyzer connected to an outdoor A/C condenser unit running R22 refrigerant, displaying suction-side temperature of 32.1°F and high-side pressure of 1732 psi; condenser coils are visibly clogged with debris.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor AC condenser unit, displaying R22 refrigerant readings of 58.7 psig / 32.7°F (low side) and 183.3 psig / 95.4°F (high side); condenser coil fins show visible debris accumulation.
- HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with refrigerant line set running up the exterior wall; the foam insulation on the suction line is visibly cracked, deteriorated, and falling apart along multiple sections.
- HVACWork status not resolved
Photograph shows a basement mechanical space with a vertical round sheet metal flue/vent pipe rising through the floor assembly, horizontal duct branches forming a tee junction, and additional ductwork runs visible in the background.
- HVACWork status not resolved
Photograph shows a mechanical room with a large sheet-metal furnace or air handler unit, overhead sheet-metal supply and return ductwork, a flue/exhaust vent pipe, black gas supply lines, and a yellow gas shutoff valve.
- HVACWork status not resolved
Photograph shows a UEI PDT650 pocket thermometer reading 49.1°F placed on galvanized sheet metal ductwork, with round duct collars visible in the background.
- HVACWork status not resolved
Photograph shows a heavily corroded exterior hose bib (spigot) mounted on the house siding, with multiple pipes and conduit penetrating through the siding and running down the foundation wall, surrounded by dense overgrowth of vines, cobwebs, and debris.
- HVACWork status not resolved
Photograph shows a UEi PDT650 pocket thermometer displaying 59.5°F, positioned against galvanized sheet metal ductwork with visible screws along a seam.
- HVACWork status not resolved
Photograph shows the exterior condenser coil fins of an outdoor HVAC unit heavily clogged with dry grass, straw, and organic debris, which can restrict airflow and reduce system efficiency.
- HVACWork status not resolved
Photograph shows a Run Test Analysis & Conditions label affixed to a gray metal enclosure Final Charge field is blank
- HVACWork status not resolved
Photograph shows a UEI PDT650 pocket thermometer displaying 83.4°F, resting on a dark sheet metal surface outdoors on grass, consistent with an HVAC temperature measurement.
- UnclassifiedWork status not resolved
Photograph shows a UEI PDT650 pocket thermometer resting on a metal frame outdoors, displaying a temperature reading of 42.6°F, surrounded by dry leaves and sparse ground vegetation.
- UnclassifiedWork status not resolved
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condenser unit, displaying R22 refrigerant readings: low-side 58.7 psi and high-side 183.5 psi with a subcooling (SC) value of 13.2°F.
- HVACWork status not resolved