10322 Oxford Hill Drive
Across 12 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 12 documented records
Fresh House Property Summary
Highlights selected from 12 documented records for this property.
- HVAC · Outdoor AC condensing unit and coil replaced, old unit 30-plus years old · Aug 2022
- HVAC · New condensing unit and coil installed again the following year · May 2023
- HVAC · Furnace replacement proposed for 1982-era unit · Aug 2022
- HVAC · Furnace and coil replacement proposed after rusted heat exchanger found · Nov 2023
- HVAC · Outdoor AC unit found with failed capacitor and non-running fan motor · Aug 2022
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 12 documented records for 10322 Oxford Hill Drive, St. Louis, MO 63146, dated from August 2022 through November 2023. The amount summary includes $23,174.22 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Visit — Outdoor unit needs cleaning
- HVAC
Built from Housecall Pro data
- $50HVACTenants not home; both indoor and outdoor units were working, the outdoor unit mechanically needs cleaning, and both water outlets within reach are not working.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service — Outdoor fan motor not running; 30+ yr unit
- HVAC
Built from Housecall Pro data
- $50HVACNo AC call: outdoor fan motor was not running; replaced the capacitor and checked voltage, fan still not working; unit is 30+ years old and AC coil replacement recommended, furnace still functioning.
- HVACPhotograph shows an outdoor HVAC condenser unit with its top panel and fan blade removed, exposing heavily debris-clogged condenser coils, a detached fan motor with warning label, refrigerant lines, and a visibly rusted compressor dome at the base.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork — Installed a 2 ton R410A condensing unit and cased
- HVAC
Built from Housecall Pro data
- $3,491HVACInstalled a 2 ton R410A condensing unit and cased coil in place of a 30-plus-year-old unit whose parts could not be found, including fused disconnect, electrical whip, sheet metal work to adapt the coil to ductwork, and chemical flush and pressure test of the line set.
Documented warranty5 year / 10 year / 20 yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Leak Diagnosis — Coil leak found; low on R22
- HVAC
Built from Housecall Pro data
- $50HVACNo AC call: unit found low on R22, coil pulled to search for leak and a leak found in a joint on the front side of the coil; coil needs replacement, system to be charged the next day.
- HVACFieldpiece app refrigerant measurements show R-22 system with suction pressure 58.3 psig, liquid pressure 245.7 psig, actual superheat 21.9°F, and actual subcooling 19.1°F.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — 80% gas furnace replacing 1982 unit
- HVAC
Built from Housecall Pro data
- $2,995HVACWork performed: OH2201 (Currently there is a furnace dated 1982 installed on this unit); Furnace Only 50,000/75,000 BTU 80% - 80% Furnace Only 50,000/75,000 BTU (We propose to install the following equipment in listed unit); Oxford, Description - Furnace Only (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
Documented warranty5 year / 10 year / 20 yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Coil Replacement — R22 piston coil replaced with retrofit coil
- HVAC
Built from Housecall Pro data
- $2,237HVACReplaced R22 piston coil with a retrofit uncased piston coil on the unit and supplied R22 refrigerant (2 pounds).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Diagnostic — Flame rollout caused fan control failure
- HVAC
Built from Housecall Pro data
- $50HVACNo heat call: flame roll out on the unit caused fan control failure and unsafe unit operation; due to the unit's age, a system rebuild would exceed the cost of replacement.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Bad safety service call, 0.5 hr labor
- HVAC
Built from Housecall Pro data
- $50HVACService call (job OH2207, 'Bad safety') with half an hour of labor performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — 80% gas furnace and coil installed
- HVAC
Built from Housecall Pro data
- $3,591HVACWork performed: OH2206/ WTN - 61682218; Oxford, Furnace 80%/Coil Piston - Furnace/Coil Cased and Uncased 50,000/75,000 BTU (We propose to install the following equipment in above listed unit); Install Desc - Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
Documented warranty5 year / 10 year / 20 yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 2-ton R410A condenser installed
- HVAC
Built from Housecall Pro data
- $3,341HVACInstalled a Sure Comfort by Rheem/WeatherKing 2 ton R410A condensing unit with matching piston, including pad, electrical whip and fused disconnect; leveled unit, flushed line set and charged system to factory recommendations.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC AC/Coil Replacement — 2-ton R410A condenser and coil replaced
- HVAC
Built from Housecall Pro data
- $3,924HVACWork performed: Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Warranty (Equipment Warranty); Payment Terms Net 30/45; Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — Furnace replaced; rusted heat exchanger
- HVAC
Built from Housecall Pro data
- $3,345HVACWork performed: OH22-7 / P.O. 2054749 (Current system, unit has rusted out heat exchanger and fuel rail); Furnace/Coil Cased and Uncased 50,000/75,000 BTU (We propose to install the following equipment in above listed unit); Warranty (Equipment Warranty); Payment Terms Net 30/45; Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.