← MAP

1210 Oxford Hill Court

St. Louis, MO 6314638.6818°N, 90.4058°W
16Events
Contributed by:1 contributor
$33kDocumented amounts
SOURCE-BACKED RECORDS

Across 16 records on this home

Completed work

Invoices and paid receipts

$33k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 16 documented records

Fresh House Property Summary

Highlights selected from 16 documented records for this property.

  • HVAC
    HVAC · Full AC, coil and furnace replaced after unsafe unit found · Jun 2023$5.9k
  • HVAC
    HVAC · Furnace and coil installed with new gas, electrical and flue connections · Jul 2022
  • HVAC
    HVAC · Old indoor coil swapped from R22 to R410A refrigerant · Jul 2022
  • Plumbing
    Plumbing · New water heater installed with expansion tank and gas line · Mar 2024
  • HVAC
    HVAC · AC condenser and coil replaced again due to mixed refrigerant and compressor failure · Apr 2024
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 1210 Oxford Hill Court. I only speak from this property's source-backed records — 16 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

16 documented events
Contributed by: 1 contributor
First documented event: Jul 2022
Latest documented event: Apr 2024
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 16 documented records for 1210 Oxford Hill Court, St. Louis, MO 63146, dated from July 2022 through April 2024. The amount summary includes $32,544.72 in completed work across HVAC and Plumbing; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Ductwork Inspection — Airflow issues partly from aging furnace

Document dated Jul 1, 2022Uploaded Nov 10, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $65
  • HVACInspected ductwork built into ceiling and wall; airflow problems are caused partially by aging furnace coil.
    $65
  • HVACan EnergyGuide sticker is affixed to the front panel
Attached photo 1HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — AC system frozen over; needs cleaning

Document dated Jul 13, 2022Uploaded Nov 10, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACService call for no AC: system found completely frozen over and turned off to thaw overnight; outdoor unit needs cleaning and charge adjusted.
    $50
  • HVACPhotograph shows a refrigerant suction line with deteriorated insulation and visible ice/frost accumulation at two points; at the wall penetration and near the top of the line; adjacent to a sheet metal air handler cabinet with ductwork and control wiring visible in the background.
  • HVACPhotograph shows exterior wall-mounted conduit runs with multiple unsecured wires (black, white, green/teal) hanging loosely from conduit bodies at the brick-stucco transition, with a small junction/disconnect box at the base.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC · document context

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Blower Cleaning — Old rusted furnace; weak airflow after cleaning

Document dated Jul 13, 2022Uploaded Nov 10, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $100
  • HVACRemoved and cleaned blower and coil and inspected heat exchanger; airflow to back of apartment still weak, furnace very old with a lot of rust, and replacement with a stronger blower motor furnace would help airflow.
    $100
  • HVACFieldpiece app air-side psychrometric measurements show return dry bulb 70.3°F, supply dry bulb 55.3°F, Delta T 15.0°F, with return enthalpy 26.6 Btu/lbm and supply enthalpy 22.3 Btu/lbm.
Attached photo 1HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Installation — 80% gas furnace and coil installed

Document dated Jul 20, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,591
  • HVACInstalled an 80% natural gas furnace with cased/uncased piston coil, including sheet metal adaptation, new gas shut off and gas pipe, electrical switch and power, and flue work to existing lines.
    $3,591
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 20, 2022HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Disconnect reset; R-22 recharged

Document dated Jul 21, 2022Uploaded Nov 10, 20265 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $238
  • HVACNo AC call: found the disconnect pulled and put it back in, system ran; checked system charge, found it slightly low on R22, and charged the system with R-22 refrigerant so it functioned as intended.
    $238
  • HVACcondenser coils and refrigerant hoses are visible in the background
  • HVACPhotograph shows a heavily corroded and deteriorated condenser coil assembly removed from its housing and elevated on a metal stand, alongside a newer condenser unit on the ground and a second unit visible in the background, with tools present suggesting active service work.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Control Board Repair — Blower motor out of specs; replace soon

Document dated Jul 22, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $500
  • HVACReplaced the furnace control board, indoor blower capacitor and thermostat for a no-AC call; system working in cool mode, blower motor amp draws out of spec and running slower than intended, replacement recommended soon.
    $500

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Coil Replacement — Indoor coil replaced to 410A, system recharged

Document dated Jul 25, 2022Uploaded Nov 10, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $2,200
  • HVACReplaced the old R22 indoor coil with a 410A coil and recharged the system with new refrigerant to match the R410A outdoor unit.
    $2,200
  • HVACPhotograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge displaying R410A refrigerant readings: low-side 106.9 PSIG (13.1°F superheat, 34.7°F VSAT), high-side 272.3 PSIG (7.0°F subcooling, 89.2°F LSAT), with outdoor ambient 78.4°F, suction line temp 47.8°F, and liquid line temp 82.2°F.
Attached photo 1HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Repair Invoice — Blower motor replaced; AC working

Document dated Aug 9, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $671
  • HVACServiced a no-cooling AC call with a frozen unit; found a failing blower motor, and after the motor was replaced the system was working as intended.
    $671

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Visit — Equipment working as intended, no repair needed

Document dated Aug 16, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACService visit performed; all equipment is working as intended at this point, no recommended repair needed.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Cleaned safeties, gas pressure, relit pilot

Document dated Dec 23, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $75
  • HVACCleaned safeties, adjusted and checked gas pressure, and relit the system pilot light; all systems were working as intended at completion.
    $75

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Furnace Replacement — 80% gas furnace and coil installed

Document dated Jan 9, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,591
  • HVACWork performed: OH1008/ WTN - 62980950; Oxford, Furnace 80%/Coil Piston - Furnace/Coil Cased and Uncased 50,000/75,000 BTU (We propose to install the following equipment in above listed unit); Install Desc - Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
    $3,591
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Jan 9, 2023HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Condenser and Coil Replacement — 2-ton condenser and coil

Document dated Apr 25, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,924
  • HVACWork performed: OH1004 / P.O. 1920517 (Job Completed); Oxford, 13 Seer Condenser/Coil Only - Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
    $3,924
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Apr 25, 2023HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Full System Replacement — 2-ton 13 SEER A/C + 80% furnace

Document dated May 15, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $5,692
  • HVACWork performed: OH1010 / P.O. 1922030 (Full System Replacement AC/Coil/Furnace); Oxford, Full 80% 13 Seer R410A - Oxford Full Install 2 Ton R410A 80% 50,000/75,000 BTU (We propose to install the follow equipment in listed unit); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
    $5,692
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · May 15, 2023HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Replacement — 2-ton AC, coil and air handler replaced

Document dated Jun 15, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $5,924
  • HVACFull AC, coil and furnace replacement; installed a 2-ton 13/2 SEER air handler with 10KW heat and condenser because the current unit was unsafe for use.
    $5,924
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Jun 15, 2023HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “All equipment installed by Contractor comes with a manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Plumbing

Plumbing Water Heater Installation — 40/50 gallon water heater

Document dated Mar 19, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented Plumbing at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • Plumbing
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $1,950
  • PlumbingInstalled a 40/50 gallon gas/electric water heater, attached to existing copper lines with flex lines using the existing flue, including gas line, expansion tank and other code requirements.
    $1,950

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC AC Replacement — 2-ton R410A condenser and coil AC replacement

Document dated Apr 1, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,924
  • HVACReplaced the AC with a Sure Comfort by Rheem/WeatherKing 2 ton R410A condensing unit and 2 ton cased/uncased coil, after the old AC had mixed refrigerant and a compressor shutting off on high limit.
    $3,924
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Apr 1, 2024HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “All equipment installed by Contractor comes with a manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Plumbing
✓ documented
HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history