Complete public upload archive

Property records for 1210 Oxford Hill Court, St. Louis, MO 63146

All 16 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 16.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record09

HVAC Ductwork Inspection — Airflow issues partly from aging furnace

  • HVAC

On July 1, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$65

    Inspected ductwork built into ceiling and wall; airflow problems are caused partially by aging furnace coil.

  • HVACWork status not resolved

    an EnergyGuide sticker is affixed to the front panel

Record 2Public property record02

HVAC Service Call — AC system frozen over; needs cleaning

  • HVAC

On July 13, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$50

    Service call for no AC: system found completely frozen over and turned off to thaw overnight; outdoor unit needs cleaning and charge adjusted.

  • HVACWork status not resolved

    Photograph shows a refrigerant suction line with deteriorated insulation and visible ice/frost accumulation at two points — at the wall penetration and near the top of the line — adjacent to a sheet metal air handler cabinet with ductwork and control wiring visible in the background.

  • HVACWork status not resolved

    Photograph shows exterior wall-mounted conduit runs with multiple unsecured wires (black, white, green/teal) hanging loosely from conduit bodies at the brick-stucco transition, with a small junction/disconnect box at the base.

  • UnclassifiedWork status not resolved

    Photograph shows a blurry interior cavity (possibly crawl space or wall cavity) with a rough-textured, dark-colored wood structural member in the foreground and a light-colored surface visible in the background, along with what appears to be metal framing at the upper left.

Record 3Public property record09

HVAC Blower Cleaning — Old rusted furnace; weak airflow after cleaning

  • HVAC

On July 13, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$100

    Removed and cleaned blower and coil and inspected heat exchanger; airflow to back of apartment still weak, furnace very old with a lot of rust, and replacement with a stronger blower motor furnace would help airflow.

  • HVACWork status not resolved

    Fieldpiece app air-side psychrometric measurements show return dry bulb 70.3°F, supply dry bulb 55.3°F, Delta T 15.0°F, with return enthalpy 26.6 Btu/lbm and supply enthalpy 22.3 Btu/lbm.

Record 4Public property record09

HVAC Installation — 80% gas furnace and coil installed

  • HVAC

On July 20, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$3,591

    Installed an 80% natural gas furnace with cased/uncased piston coil, including sheet metal adaptation, new gas shut off and gas pipe, electrical switch and power, and flue work to existing lines.

Record 5Public property record05

HVAC Service Call — Disconnect reset; R-22 recharged

  • HVAC

On July 21, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$238

    No AC call: found the disconnect pulled and put it back in, system ran; checked system charge, found it slightly low on R22, and charged the system with R-22 refrigerant so it functioned as intended.

  • HVACWork status not resolved

    condenser coils and refrigerant hoses are visible in the background

  • HVACWork status not resolved

    Photograph shows a heavily corroded and deteriorated condenser coil assembly removed from its housing and elevated on a metal stand, alongside a newer condenser unit on the ground and a second unit visible in the background, with tools present suggesting active service work.

  • HVACWork status not resolved
Record 6Public property record04

HVAC Control Board Repair — Blower motor out of specs; replace soon

  • HVAC

On July 22, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$500

    Replaced the furnace control board, indoor blower capacitor and thermostat for a no-AC call; system working in cool mode, blower motor amp draws out of spec and running slower than intended, replacement recommended soon.

Record 7Public property record02

HVAC Coil Replacement — Indoor coil replaced to 410A, system recharged

  • HVAC

On July 25, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$2,200

    Replaced the old R22 indoor coil with a 410A coil and recharged the system with new refrigerant to match the R410A outdoor unit.

  • HVACWork status not resolved

    Photograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge displaying R410A refrigerant readings: low-side 106.9 PSIG (13.1°F superheat, 34.7°F VSAT), high-side 272.3 PSIG (7.0°F subcooling, 89.2°F LSAT), with outdoor ambient 78.4°F, suction line temp 47.8°F, and liquid line temp 82.2°F.

Record 8Public property record04

HVAC Repair Invoice — Blower motor replaced; AC working

  • HVAC

On August 9, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$671

    Serviced a no-cooling AC call with a frozen unit; found a failing blower motor, and after the motor was replaced the system was working as intended.

Record 9Public property record08

HVAC Service Visit — Equipment working as intended, no repair needed

  • HVAC

On August 16, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$50

    Service visit performed; all equipment is working as intended at this point, no recommended repair needed.

Record 10Public property record08

HVAC Service Call — Cleaned safeties, gas pressure, relit pilot

  • HVAC

On December 23, 2022, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$75

    Cleaned safeties, adjusted and checked gas pressure, and relit the system pilot light; all systems were working as intended at completion.

Record 11Public property record08

HVAC Furnace Replacement — 80% gas furnace and coil installed

  • HVAC

On January 9, 2023, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$3,591

    Work performed: OH1008/ WTN - 62980950; Oxford, Furnace 80%/Coil Piston - Furnace/Coil Cased and Uncased 50,000/75,000 BTU (We propose to install the following equipment in above listed unit); Install Desc - Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).

Record 12Public property record04

HVAC Condenser and Coil Replacement — 2-ton condenser and coil

  • HVAC

On April 25, 2023, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$3,924

    Work performed: OH1004 / P.O. 1920517 (Job Completed); Oxford, 13 Seer Condenser/Coil Only - Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).

Record 13Public property record10

HVAC Full System Replacement — 2-ton 13 SEER A/C + 80% furnace

  • HVAC

On May 15, 2023, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$5,692

    Work performed: OH1010 / P.O. 1922030 (Full System Replacement AC/Coil/Furnace); Oxford, Full 80% 13 Seer R410A - Oxford Full Install 2 Ton R410A 80% 50,000/75,000 BTU (We propose to install the follow equipment in listed unit); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).

Record 14Public property record05

HVAC Replacement — 2-ton AC, coil and air handler replaced

  • HVAC

On June 15, 2023, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$5,924

    Full AC, coil and furnace replacement; installed a 2-ton 13/2 SEER air handler with 10KW heat and condenser because the current unit was unsafe for use.

Record 15Public property record8

Plumbing Water Heater Installation — 40/50 gallon water heater

  • Plumbing

On March 19, 2024, ASSURED HEATING AND COOLING documented Plumbing at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • PlumbingCompleted work$1,950

    Installed a 40/50 gallon gas/electric water heater, attached to existing copper lines with flex lines using the existing flue, including gas line, expansion tank and other code requirements.

Record 16Public property record8

HVAC AC Replacement — 2-ton R410A condenser and coil AC replacement

  • HVAC

On April 1, 2024, ASSURED HEATING AND COOLING documented HVAC at 1210 Oxford Hill Court, St. Louis, MO 63146.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$3,924

    Replaced the AC with a Sure Comfort by Rheem/WeatherKing 2 ton R410A condensing unit and 2 ton cased/uncased coil, after the old AC had mixed refrigerant and a compressor shutting off on high limit.

View 1210 Oxford Hill Court, St. Louis, MO 63146 on Fresh House