- HVAC · AC stopped working due to burnt wire and failed breaker in electrical panel · Sep 2025
- HVAC · Electrician needed to install new 25-amp double-pole breaker · Sep 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 10366 Ashbrook Drive, St. Louis, MO 63137, dated in September 2025. The amount summary includes $219 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Burnt wire and bad breaker in panel
- HVAC
Built from Housecall Pro data
- $219HVACService call for no AC: system ran mechanically but tripped the breaker; outdoor unit compressor and fan amps tested fine, and a burnt wire and bad breaker were found in the electrical panel, needing an electrician to install a new 25 amp double pole breaker.
- HVACPhotograph shows the interior of an electrical panel with a severely burned and charred bus bar or breaker component, with visible scorching, melted material, and heat damage; a significant electrical safety hazard.
- HVACPhotograph shows the interior of an electrical panel with multiple conductors (red, gray, yellow, white, bare copper) routed in a disorganized manner, a pink paper tag attached to a yellow cable near the panel bottom, circuit breakers along the left side, and debris/dust accumulation at the base of the enclosure.
- HVACPhotograph shows the interior of an electrical panel with visible charring and burned/melted insulation on a conductor near the breaker bus, indicating a prior or active overheating event; a red wire nut is also visible inside the panel.
- HVACPhotograph shows a circuit breaker removed from panel lying on a concrete ledge, with visible burn damage and melted insulation on the attached wiring at the connection point.
- HVACPhotograph shows a Fluke 116 True RMS Multimeter reading 40.1 μF (microfarads) in capacitance mode, being used to test a capacitor on an outdoor AC condenser unit; tools and wiring are visible near the condenser fan grille.
- HVACwiring is visible on the right side of the panel
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.