  • HVAC
    HVAC · AC system replaced with new condenser, coil, and disconnect · Jul 2022
  • HVAC
    HVAC · Full HVAC system replaced with new furnace, condensing unit, and coil · Jul 2023
  • HVAC
    HVAC · HVAC control board replaced on service visit · Jun 2023
  • HVAC
    HVAC · System recharged with R407C refrigerant on service visit · Jul 2022
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 10370 Oxford Hill Drive. I only speak from this property's source-backed records — 8 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

8 documented events
Contributed by: 1 contributor
First documented event: Jul 2022
Latest documented event: Jul 2023
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 8 documented records for 10370 Oxford Hill Drive, St. Louis, MO 63146, dated from July 2022 through July 2023. The amount summary includes $10,368.11 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Service Call — Bad compressor found on AC system

Document dated Jul 21, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACService call for no AC, needs AC/coil; on arrival the system was found to have a bad compressor.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Refrigerant Service — Unit low on charge, R407C refrigerant added

Document dated Jul 26, 2022Uploaded Nov 10, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $250
  • HVACService call for unit low on charge; 2 pounds of R407C refrigerant supplied.
    $250
  • HVACPhotograph shows a Fieldpiece app screen displaying live refrigerant-side measurements for an R-407C system: suction pressure 62.2 psig, liquid pressure 186.2 psig, actual superheat 20.3°F, and actual subcooling 16.2°F.
Attached photo 1HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Condenser and Coil Replacement — 2-ton R410A condenser/coil

Document dated Jul 27, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,491
  • HVACInstalled a Sure Comfort by Rheem/WeatherKing 2 ton R410A condenser and coil to replace a failed compressor on an R22 system, including fused disconnect, electrical whip, sheet metal adaptation to ductwork, and chemical flush and pressure test of the line set.
    $3,491
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 27, 2022HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — AC functioning as intended at 69 degrees

Document dated Aug 29, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACResponded to a no AC call and found the unit functioning as intended at 69 degrees.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Furnace door not seated, safety switch tripped

Document dated Sep 23, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACService call found the furnace door not seated properly, causing the safety switch to prevent the unit from working; labor was performed.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Control Board Replacement — RUUD control board replaced

Document dated Jun 8, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $428
  • HVACInspected the unit and replaced the RUUD control board, which was ordered and installed on the service date.
    $428

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Refrigerant Charge — System charged with customer-supplied R407C

Document dated Jul 14, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $125
  • HVACCharged system with customer supplied r407c refrigerant; at completion the system was running as intended, with monitoring needed for future failures.
    $125

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Full System Replacement — 2-ton A/C + 80% furnace replacement

Document dated Jul 24, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $5,924
  • HVACFull system replacement installing a 2 ton 13 SEER condensing unit, an 80% 50,000/75,000 BTU furnace and a cased coil.
    $5,924
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 24, 2023HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history