HVAC Service Call — Bad compressor found on AC system
HVAC
On July 21, 2022, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$50
Service call for no AC, needs AC/coil; on arrival the system was found to have a bad compressor.
Record 2·Public property record·09
HVAC Refrigerant Service — Unit low on charge, R407C refrigerant added
HVAC
On July 26, 2022, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$250
Service call for unit low on charge; 2 pounds of R407C refrigerant supplied.
HVACWork status not resolved
Photograph shows a Fieldpiece app screen displaying live refrigerant-side measurements for an R-407C system: suction pressure 62.2 psig, liquid pressure 186.2 psig, actual superheat 20.3°F, and actual subcooling 16.2°F.
Record 3·Public property record·08
HVAC Condenser and Coil Replacement — 2-ton R410A condenser/coil
HVAC
On July 27, 2022, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$3,491
Installed a Sure Comfort by Rheem/WeatherKing 2 ton R410A condenser and coil to replace a failed compressor on an R22 system, including fused disconnect, electrical whip, sheet metal adaptation to ductwork, and chemical flush and pressure test of the line set.
Record 4·Public property record·06
HVAC Service Call — AC functioning as intended at 69 degrees
HVAC
On August 29, 2022, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$50
Responded to a no AC call and found the unit functioning as intended at 69 degrees.
Record 5·Public property record·08
HVAC Service Call — Furnace door not seated, safety switch tripped
HVAC
On September 23, 2022, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$50
Service call found the furnace door not seated properly, causing the safety switch to prevent the unit from working; labor was performed.
Record 6·Public property record·09
HVAC Control Board Replacement — RUUD control board replaced
HVAC
On June 8, 2023, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$428
Inspected the unit and replaced the RUUD control board, which was ordered and installed on the service date.
Record 7·Public property record·09
HVAC Refrigerant Charge — System charged with customer-supplied R407C
HVAC
On July 14, 2023, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$125
Charged system with customer supplied r407c refrigerant; at completion the system was running as intended, with monitoring needed for future failures.
Record 8·Public property record·09
HVAC Full System Replacement — 2-ton A/C + 80% furnace replacement
HVAC
On July 24, 2023, ASSURED HEATING AND COOLING documented HVAC at 10370 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$5,924
Full system replacement installing a 2 ton 13 SEER condensing unit, an 80% 50,000/75,000 BTU furnace and a cased coil.