  • HVAC
    HVAC · Full AC and furnace system replaced at the apartment unit · Jun 2023$5.7k
  • HVAC
    HVAC · AC coil and condenser replaced again the following year · Aug 2024
  • Plumbing
    Plumbing · Water heater replaced with new expansion tank and gas line · May 2024
  • HVAC
    HVAC · Indoor blower motor replaced and system tested · Jun 2024
  • HVAC
    HVAC · Outdoor disconnect reinstalled and system inspected after falling · May 2024
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 10394 Oxford Hill Drive. I only speak from this property's source-backed records — 16 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

16 documented events
Contributed by: 1 contributor
First documented event: Jul 2022
Latest documented event: Jun 2024
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 16 documented records for 10394 Oxford Hill Drive, St. Louis, MO 63146, dated from July 2022 through June 2024. The amount summary includes $25,540.86 in completed work across HVAC and Plumbing; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Capacitor Repair — Bad capacitor replaced on outdoor AC unit

Document dated Jul 7, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $219
  • HVACNo AC call: outdoor unit would not turn on due to a bad capacitor; replaced the dual run capacitor (standard size up to 55 mf), checked the system, and all systems were working as intended.
    $219

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Diagnostic Service — No AC; extremely old unit low on R22

Document dated Jul 21, 2022Uploaded Nov 10, 20263 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACDiagnosed no AC: unit extremely low on R22 and extremely old; replacement quote to be sent, and charging the unit was advised against before options due to its age.
    $50
  • HVACthe air filter is removed and leaning on the floor, and visible rust/corrosion staining is present at the base of the unit and ductwork connections
  • HVACPhotograph shows an outdoor AC condenser unit mounted on a heavily rusted metal stand, with condenser coils visibly clogged with dirt and debris, refrigerant lines running up the brick wall, and overgrown vegetation surrounding the unit; a second condenser unit is partially visible to the right.
Attached photo 1HVAC
Attached photo 2HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Refrigerant Charge — R22 system recharged

Document dated Jul 22, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $500
  • HVACCharged R22 system to the best equipment would allow; at completion of service 71/250 R22.
    $500

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Repair — Shorted wires fixed, control board reattached

Document dated Aug 17, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $100
  • HVACNo AC call: found shorted wires in the switch box and control board disconnected from unit; re-attached control board and fixed the short, but could not enter unit to check system function.
    $100

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Visit — System appears to operate correctly

Document dated Sep 6, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACReturn visit to inspect equipment after the earlier fix; the unit was still not accessible on the second trip, but the system seemed to be operating correctly.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Pilot Light Service — Pilot light lit

Document dated Oct 18, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACLit the pilot light, with half an hour of labor.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Diagnostic Service — Rusted burner assembly

Document dated Oct 28, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACFound wrong pressure switch, inducer motor not coming on, faulty door switch and rusted out burner assembly; rewired door switch to try to run the unit for diagnosis, and system replacement is recommended.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Furnace Replacement — 80% gas furnace installed, 50-75k BTU

Document dated Nov 2, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $2,590
  • HVACWork performed: OH9408/ WTN- 61866722; Furnace Only 50,000/75,000 BTU 80% - 80% Furnace Only 50,000/75,000 BTU (We propose to install the following equipment in listed unit); Install Desc - Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
    $2,590
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Nov 2, 2022HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Furnace Installation — 80% gas furnace installed (50k/75k BTU)

Document dated Dec 13, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $2,490
  • HVACWork performed: Furnace Only 50,000/75,000 BTU 80% - 80% Furnace Only 50,000/75,000 BTU (We propose to install the following equipment in listed unit); Install Desc - Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
    $2,490
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Dec 13, 2022HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC System Replacement — 2-ton condenser, coil + 80% furnace

Document dated Jun 2, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $5,692
  • HVACInstalled a 2 ton R410A condensing unit, 2 ton cased/uncased coil, and 80% 75K furnace as a full system replacement at the apartment unit.
    $5,692
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Jun 2, 2023HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Furnace Replacement — Rheem 80% 75,000 BTU furnace replacement

Document dated Jul 27, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,251
  • HVACWork performed: 80% Furnace Only - 80% 75,000 BTU Furnace (We purpose to install the following equipment in your home); Install Desc - Equipment Warranty (Equipment Warranty); Apartment, Description - Payment Terms Net 30/45; Install Desc - Terms and Conditions.
    $3,251
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 27, 2023HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “All equipment installed by Contractor comes with a manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC AC/Coil Replacement — 2-ton R410A condenser and coil replaced

Document dated Sep 14, 2023Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,924
  • HVACAC/coil replacement: installed a Sure Comfort by Rheem/WeatherKing 2 ton R410A condensing unit and 2 ton cased/uncased coil.
    $3,924
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Sep 14, 2023HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Plumbing

Plumbing Water Heater Installation — 40/50 gallon water heater

Document dated May 2, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented Plumbing at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • Plumbing
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $2,050
  • PlumbingInstalled a 40/50 gallon gas/electric water heater, attached to existing copper lines with flex lines using the existing flue, including gas line, expansion tank and other code requirements.
    $2,050

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Outdoor disconnect reinstalled

Document dated May 13, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACFound the outdoor disconnect on the ground, reinstalled it and inspected the system; all systems were working as intended at completion.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Blower Motor Replacement — Lennox indoor blower motor replaced

Document dated Jun 18, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $625
  • HVACReplaced Lennox indoor blower motor and tested the system.
    $625

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Coil/Condenser Replacement — 2-ton condenser and coil replacement

Document dated Aug 16, 2024Uploaded Nov 10, 20263 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10394 Oxford Hill Drive, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $3,900
  • HVACWork performed: OH94-5 \ PO 2208030 (AC-coil replacement); Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Payment Terms Net 30/45; Equipment Warranty; Terms and Conditions.
    $3,900
  • HVACPhotograph shows a Sure-brand outdoor condenser unit mounted against a brick exterior wall, with insulated refrigerant lines, copper line sets, and a wall-mounted disconnect box; a second older condenser unit is partially visible in the foreground.
  • HVACPhotograph shows Fieldpiece app refrigerant side measurements for R-410A: suction pressure 132.1 psig, liquid pressure 355.8 psig, suction temperature 57.9°F, liquid temperature 99.3°F, vapor saturation 45.6°F, liquid saturation 107.8°F, actual superheat 12.3°F, and actual subcooling 8.5°F.
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Aug 16, 2024HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “All equipment installed by Contractor comes with a manufacturer five-year parts warranty”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

  • labor
    · source

    “Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Attached photo 1HVAC
Attached photo 2HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Plumbing
✓ documented
HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history