- HVAC · Gas furnace replaced with a new American Standard unit · Aug 2026
- HVAC · AC not cooling; wiring, refrigerant, and cooling inspected · Aug 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 10511 Lilac Avenue, St. Louis, MO 63137, dated in August 2026. The amount summary includes $4,905.85 in completed work, $500 with completion status not stated; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — After-hours HVAC diagnostic and labor
- HVAC
Built from Housecall Pro data
- $456HVACPerformed a residential after-hours diagnostic and after-hours labor for a maintenance customer at the service address.
- HVACAC is blowing warm air and not cooling properly; tenant reports the issue has returned after previous service replaced thermostat wiring from basement to AC; work order requests inspection of wiring, refrigerant, and cooling operation with repairs not to exceed stated limit.
- HVACPhotograph shows interior of an HVAC unit with multiple colored control wires routed through the cabinet, a metal junction box mounted to the frame, and significant dust and debris accumulation on the structural frame and components.
- HVACPhotograph shows the interior of a pipe as captured by a sewer camera, with a circular lateral connection opening visible on the left side and discoloration or buildup along the pipe walls.
- HVACPhotograph shows the back of a white thermostat wall plate mounted on a wall, with a multi-position screw terminal block connected to multiple low-voltage wires (brown/tan, red, green, blue, and beige) emerging from a wall opening; the plate is labeled 'USED' near the terminal block and bears part number 50062131-001.
- HVACPhotograph shows a sewer camera monitor displaying a pipe opening with heavy corrosion and rust/mineral buildup around the interior circumference; camera ambient temperature reads 118°F and timestamp reads 08-08-2026 11:31.
Financial source
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — American Standard S8X1 60,000 gas furnace
- HVAC
Built from Housecall Pro data
- $4,450HVACInstalled an American Standard Silver S8X1 60,000 gas furnace with furnace install materials, a 1" external filter rack, and 4" flue pipe and elbows.
- HVACPhotograph shows a gas furnace installed in a basement mechanical area, connected to sheet metal supply ductwork and a metal flue/exhaust pipe ductwork is labeled 'Filter 16x25x1' indicating filter location a white water heater is visible to the right
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.