- Electrical · Multiple electrical issues found including broken outlets and missing safety protection · 2026
- HVAC · Heating and cooling system with 2025 equipment functioning correctly · 2026
- Foundation · Two foundation wall cracks found needing repair · 2026
- Pest · Older termite damage found on exterior wood trim · 2026
- Plumbing · Water heater functioning properly but basement faucet leaks · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1100 South 5th Street, De Soto, MO 63020, dated in July 2026.
Home Inspection Document
On July 15, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 1100 South 5th Street, De Soto, MO 63020.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including foundation cracks, termite damage, electrical issues, a broken window seal, and missing GFCI protection; roof, HVAC, and plumbing systems generally satisfactory.
- PestWDI inspection found visible evidence of wood destroying insects: older termite damage on exterior door trim; borate-based solution treatment recommended; no live insects or frass observed.
- FoundationTwo cracks observed in the foundation wall requiring epoxy injection repair — one on the interior unfinished basement wall and one on the exterior retaining wall next to the attached garage.
- PestOlder termite damage observed on the side deck wood door trim; treatment with a borate-based solution (Bora-Care) recommended unless seller proves prior treatment.
- ElectricalMultiple electrical deficiencies noted: rear exterior GFCI outlet will not reset and needs replacement, tree limbs pushing on overhead power lines, loose living room outlet, open ground wire in living room outlet, missing GFCI in basement laundry area, and inoperable kitchen sink and rear patio light fixtures.
- RoofArchitectural shingle roof estimated 5 years old is in satisfactory condition; tree limbs contacting the structure should be trimmed to prevent debris accumulation on roof and gutters.
- HVACCentral split system with Daikin forced-air air handler (manufactured 2025) and Goodman 2-ton condenser (manufactured 2025) both functioning correctly; 200-amp Square D panel in basement.
- PlumbingRheem 50-gallon electric water heater (manufactured 2021) functioning properly; leaky bib faucet in basement laundry area needs repair or replacement; copper supply and PVC waste pipes satisfactory.
- WindowsThe window above the kitchen sink appears to have a broken seal and needs to be repaired or replaced; exterior vinyl windows otherwise satisfactory.