← MAP

116 Madison Avenue

Webster Groves, MO 6311938.6019°N, 90.3586°W
1Event
Contributed by:1 contributor
$5.4kDocumented amounts
SOURCE-BACKED RECORDS

Across 1 record on this home

Completed work

Invoices and paid receipts

$5.4k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 1 documented records

Fresh House Property Summary

Highlights selected from 1 documented record for this property.

  • HVAC
    HVAC · Air conditioner and evaporator coil replaced with new disconnect · Jun 2026$5.4k
  • HVAC
    HVAC · Condenser unit visible outside; indoor air handler and duct connections documented · 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 116 Madison Avenue. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jun 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 116 Madison Avenue, Webster Groves, MO 63119, dated in June 2026. The amount summary includes $5,400 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Work — 2-ton American Standard AC + evaporator coil

Document dated Jun 19, 2026Uploaded Nov 8, 202611 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 116 Madison Avenue, Webster Groves, MO 63119.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $5,400
  • HVACSupplied an American Standard evaporator coil and 2-ton air conditioner with condenser pad, 30-amp disconnect, misc AC materials, and journeyman and apprentice labor.
    $5,400
  • HVACPhotograph shows an aged exterior air conditioning condenser unit positioned along the home's foundation wall, with a disconnect box mounted on the siding; the unit and surrounding area are heavily overgrown with ivy and covered in debris and dead leaves.
  • HVACFieldpiece app refrigerant side measurements show R-454B refrigerant with suction pressure 129.7 psig, liquid pressure 292.3 psig, actual superheat 15.1°F, and actual subcooling 10.2°F.
warranty5 years / 10 yearsFrom invoiceView details
Documented warrantyfrom invoice · Jun 19, 2026HVAC · 2 terms

What this warranty covers

5 years
  • Coil and Parts
    · source

    “Warranty Period: Coil and Parts - 5 years.”

10 years
  • Coil and Parts
    · source

    “Warranty Period: Coil and Parts - 10 years”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+6

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history