Property records for 116 Madison Avenue, Webster Groves, MO 63119

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Work — 2-ton American Standard AC + evaporator coil

  • HVAC

On June 19, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 116 Madison Avenue, Webster Groves, MO 63119.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$5,400

    Supplied an American Standard evaporator coil and 2-ton air conditioner with condenser pad, 30-amp disconnect, misc AC materials, and journeyman and apprentice labor.

  • HVACWork status not resolved

    Photograph shows an aged exterior air conditioning condenser unit positioned along the home's foundation wall, with a disconnect box mounted on the siding; the unit and surrounding area are heavily overgrown with ivy and covered in debris and dead leaves.

  • HVACWork status not resolved

    Fieldpiece app refrigerant side measurements show R-454B refrigerant with suction pressure 129.7 psig, liquid pressure 292.3 psig, actual superheat 15.1°F, and actual subcooling 10.2°F.

  • HVACWork status not resolved

    Photograph shows a large galvanized sheet metal air handler/plenum unit in a basement, with a black pipe running vertically along its side, a white flexible hose at the base, and a round flexible duct visible to the upper left

  • HVACWork status not resolved

    Photograph shows sheet metal HVAC ductwork in a basement mechanical area, including a rectangular plenum trunk, a round elbow transition fitting, and foil-backed tape sealing the duct joints; a flexible metallic conduit is visible along the left wall.

  • HVACWork status not resolved

    Photograph shows a gas furnace installed in a basement utility area, with a metal flue pipe and sheet metal supply ductwork overhead; the surrounding space is heavily cluttered with boxes and miscellaneous stored items.

  • HVACWork status not resolved

    Photograph shows a newly fabricated sheet metal plenum/transition assembly connected to an air handler or furnace in a basement, with seams sealed using Shurtape SF 686 / 181B-FX foil-backed duct tape and a round galvanized branch duct extending to the right.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC unit's refrigerant lines, displaying left/right pressures of 2013 and 2020 psi with a pressure differential (Δp) of 0.7 psi over a 15-minute elapsed time, consistent with a refrigerant pressure test or leak check in progress.

  • HVACWork status not resolved

    Photograph shows a gas furnace unit installed in a basement, connected to galvanized sheet metal ductwork and a foil-tape-wrapped plenum above; flexible metallic conduit is visible on the left side.

  • HVACWork status not resolved

    Photograph shows an upflow gas furnace installed in a basement, connected to sheet metal supply and return ductwork with foil-faced duct board insulation; a black flue pipe and electrical wiring are visible, and a water heater is partially visible to the left.

  • HVACWork status not resolved

    Photograph shows a furnace unit in a basement connected to sheet metal flue/exhaust vent pipes and a large rectangular sheet metal plenum/trunk duct system overhead.