← MAP

1166 West Gannon Drive

Festus, MO 6302838.2105°N, 90.4040°W
1Event
Contributed by:1 contributor
$280Documented amounts
SOURCE-BACKED RECORDS

Across 1 record on this home

Completed work

Invoices and paid receipts

None documented yet

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

$280

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 1 documented records

Fresh House Property Summary

Highlights selected from 1 documented record for this property.

  • HVAC
    HVAC · Air conditioner inspected, coils cleaned, refrigerant charge checked · Jul 2026
  • HVAC
    HVAC · AC contactor, capacitor, and motor outputs checked during service · Jul 2026
  • HVAC
    HVAC · Refrigerant charge and airflow measured within acceptable targets · 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 1166 West Gannon Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 1166 West Gannon Drive, Festus, MO 63028. The amount summary includes $280 in estimates; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Maintenance Invoice — A/C inspection and coil cleaning

Document dated Jul 27, 2026Uploaded Nov 8, 20268 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 1166 West Gannon Drive, Festus, MO 63028.
Scope
  • HVAC

Built from Housecall Pro data

Total documented value on this timeline entry: $280
  • HVACA la carte air conditioning inspection and cleaning: checked air conditioner operation, cleaned coils, and checked refrigerant charge, contactor, capacitor and motor outputs.
    $280
  • HVACFieldpiece app measurements show R-410A system with 371.0 psig discharge pressure; air-side diagnostics indicate adequate airflow across the evaporator coil (dry bulb 58.8°F vs. target 55.9°F), and refrigerant diagnostics indicate adequate charge for a TXV/EXV metering device with actual subcooling close to target subcooling of 10.0°F.
  • HVACPhotograph shows two multi-pole contactors with visibly oxidized, heat-discolored copper contacts and terminal connections, along with multiple multi-colored wires (yellow, black, blue, brown) and a small relay component with red spade connectors, consistent with an HVAC or electrical equipment enclosure.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+3

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history