HVAC Maintenance Invoice — A/C inspection and coil cleaning
- HVAC
On July 27, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1166 West Gannon Drive, Festus, MO 63028.
- Record date
Available findings
- HVACCompleted work$280
A la carte air conditioning inspection and cleaning: checked air conditioner operation, cleaned coils, and checked refrigerant charge, contactor, capacitor and motor outputs.
- HVACWork status not resolved
Fieldpiece app measurements show R-410A system with 371.0 psig discharge pressure; air-side diagnostics indicate adequate airflow across the evaporator coil (dry bulb 58.8°F vs. target 55.9°F), and refrigerant diagnostics indicate adequate charge for a TXV/EXV metering device with actual subcooling close to target subcooling of 10.0°F.
- HVACWork status not resolved
Photograph shows two multi-pole contactors with visibly oxidized, heat-discolored copper contacts and terminal connections, along with multiple multi-colored wires (yellow, black, blue, brown) and a small relay component with red spade connectors, consistent with an HVAC or electrical equipment enclosure.
- HVACWork status not resolved
Photograph shows Fieldpiece app screen displaying live R-410A refrigerant measurements: suction pressure 138.6 psig, liquid pressure 371.1 psig, actual superheat 18.7°F, actual subcooling 12.0°F, and Delta T 14.1°F.
- HVACWork status not resolved
Photograph shows the interior electrical compartment of an HVAC unit with two multi-pole contactors, copper contact points, and multiple colored control and power wires (yellow, blue, brown, black, gray, white, red) connected to terminal screws; wire labeled 'L2' is visible.
- HVACWork status not resolved
Fieldpiece app refrigerant diagnostic shows R-410A system with Delta T 14.2°F, suction pressure 138.3 psig, liquid pressure 368.4 psig, actual superheat 18.8°F, and actual subcooling 12.4°F.
- HVACWork status not resolved
data plate indicates 208/230V 3-phase, SEER 14, AHRI Certified, Energy Star compliant, natural gas-fired
- HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter clamped around wiring inside an open HVAC equipment panel, displaying a reading of 2.7 AAC; a control board with multicolored wiring is visible in the background of what appears to be an outdoor or rooftop unit.