1168 Ursula Avenue
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · HVAC diagnostic service performed on the system · Jul 2026
- HVAC · Compressor diagnosed as failed after prior leak repair and recharge · 2026
- HVAC · Evap coil replacement or full AC system replacement proposed · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1168 Ursula Avenue, University City, MO 63130, dated in July 2026. The amount summary includes $224 in completed work across HVAC, $2,385 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
Built from Housecall Pro data
- $224HVACPerformed a residential diagnostic service with residential hourly labor.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against a painted concrete block foundation wall, with refrigerant and electrical lines running up to a wall-mounted disconnect box; leaf debris is accumulated around the base and vegetation/weeds are growing in close proximity to the unit.
- HVACPhotograph shows the data plate of an outdoor central air conditioning condensing unit, Model No. TCGD24S41S3A, Serial No. W1D0770771, using R-410A refrigerant with a factory charge of 3 lbs 13 oz, rated 208-230V 1PH 60HZ, minimum circuit ampacity 12.4, max fuse/CKT BKR 20.
- HVACPhotograph shows a basement furnace unit with its lower access panel open exposing internal components and wiring, connected to a large sheet metal supply plenum and ductwork above, with a round flue pipe and refrigerant line set also visible.
- HVACPhotograph shows a basement furnace unit with its front access panel removed and leaning against the cabinet, exposing internal wiring, controls, and heat exchanger components; a round metal flue pipe exits the top of the unit and runs horizontally, connecting to sheet metal supply ductwork above.
- HVACPhotograph shows the data plate of an outdoor air conditioner condenser unit, Model No. TCGD24S41S3A, Serial No. W1D0770771, factory charged with 3 lbs 13 oz R-410A, rated 208-230V 1PH 60HZ with a minimum circuit ampacity of 12.4 and max fuse/breaker of 20A.
- HVACPhotograph shows galvanized sheet metal rectangular ductwork (plenum/trunk) with a round metal elbow pipe connected to it, and a white pipe penetrating the wall, located in a utility or basement area.
- HVACPhotograph shows a furnace data plate with model KG7SA 072C-24B1, serial KGD110800598, rated 72000 BTUH input and 57600 BTUH output, natural gas, 115 VAC / 60 HZ / 1 PH / 11.6 AMPS MAX.
- HVACPhotograph shows an outdoor AC condenser unit mounted on a pad along the building exterior, with copper refrigerant lines running along the wall whose black foam insulation is visibly deteriorated and peeling away; overgrown vegetation surrounds the unit and lines.
- HVACG8G110801129) and a pink caution label specifying R-410A refrigerant; R-22 must not be used in this system
- HVACPhotograph shows a metal pipe passing through a concrete or masonry wall with surrounding sealant/patching material that appears cracked and discolored with dark staining; a smaller pipe stub with similar patching is visible above.
- HVACPhotograph shows black-insulated pipes connected at a brass ball valve with visible moisture droplets on the copper pipe surface, multiple small-diameter white tubes fanning through joist bays, and a large black flexible hose running below the framing.
- HVACTechnician diagnosed a failed compressor not pumping properly after recent leak repair and refrigerant recharge; work order requests compressor repair and full system replacement options for owner review.
- HVACTechnician diagnosed a failed compressor not pumping properly after recent leak repair and refrigerant recharge; two options (compressor repair and full system replacement) to be provided for owner review.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement Estimate — 2-ton evap coil or 14 SEER2 A/C options
- HVAC
Options: Evap Coil $2,385 · 14 SEER 2-ton Air Conditioner and Coil $6,746.45 (all expired)
Built from Housecall Pro data
- $2,385HVACEstimate for two options: an evap coil replacement with refrigerant and filter drier, and a 14 SEER 2-ton American Standard air conditioner and coil installation with condenser pad and 30-amp disconnect.