HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
On July 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1168 Ursula Avenue, University City, MO 63130.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$224
Performed a residential diagnostic service with residential hourly labor.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against a painted concrete block foundation wall, with refrigerant and electrical lines running up to a wall-mounted disconnect box; leaf debris is accumulated around the base and vegetation/weeds are growing in close proximity to the unit.
- HVACWork status not resolved
Photograph shows the data plate of an outdoor central air conditioning condensing unit, Model No. TCGD24S41S3A, Serial No. W1D0770771, using R-410A refrigerant with a factory charge of 3 lbs 13 oz, rated 208-230V 1PH 60HZ, minimum circuit ampacity 12.4, max fuse/CKT BKR 20.
- HVACWork status not resolved
Photograph shows a basement furnace unit with its lower access panel open exposing internal components and wiring, connected to a large sheet metal supply plenum and ductwork above, with a round flue pipe and refrigerant line set also visible.
- HVACWork status not resolved
Photograph shows a basement furnace unit with its front access panel removed and leaning against the cabinet, exposing internal wiring, controls, and heat exchanger components; a round metal flue pipe exits the top of the unit and runs horizontally, connecting to sheet metal supply ductwork above.
- HVACWork status not resolved
Photograph shows the data plate of an outdoor air conditioner condenser unit, Model No. TCGD24S41S3A, Serial No. W1D0770771, factory charged with 3 lbs 13 oz R-410A, rated 208-230V 1PH 60HZ with a minimum circuit ampacity of 12.4 and max fuse/breaker of 20A.
- HVACWork status not resolved
Photograph shows galvanized sheet metal rectangular ductwork (plenum/trunk) with a round metal elbow pipe connected to it, and a white pipe penetrating the wall, located in a utility or basement area.
- HVACWork status not resolved
Photograph shows a furnace data plate with model KG7SA 072C-24B1, serial KGD110800598, rated 72000 BTUH input and 57600 BTUH output, natural gas, 115 VAC / 60 HZ / 1 PH / 11.6 AMPS MAX.
- HVACWork status not resolved
Photograph shows an outdoor AC condenser unit mounted on a pad along the building exterior, with copper refrigerant lines running along the wall whose black foam insulation is visibly deteriorated and peeling away; overgrown vegetation surrounds the unit and lines.
- HVACWork status not resolved
G8G110801129) and a pink caution label specifying R-410A refrigerant — R-22 must not be used in this system
- HVACWork status not resolved
Photograph shows a metal pipe passing through a concrete or masonry wall with surrounding sealant/patching material that appears cracked and discolored with dark staining; a smaller pipe stub with similar patching is visible above.
- HVACWork status not resolved
Photograph shows black-insulated pipes connected at a brass ball valve with visible moisture droplets on the copper pipe surface, multiple small-diameter white tubes fanning through joist bays, and a large black flexible hose running below the framing.
- HVACWork status not resolved
Technician diagnosed a failed compressor not pumping properly after recent leak repair and refrigerant recharge; work order requests compressor repair and full system replacement options for owner review.
- HVACWork status not resolved
Technician diagnosed a failed compressor not pumping properly after recent leak repair and refrigerant recharge; two options (compressor repair and full system replacement) to be provided for owner review.